Chemiluminescent labeled-antibody assay for thyroxin in serum, with magnetic separation of the solid-phase.

نویسندگان

  • M L Sturgess
  • I Weeks
  • C N Mpoko
  • I Laing
  • J S Woodhead
چکیده

A chemiluminescent labeled-antibody immunoassay has been developed for measurement of total thyroxin (T4) in serum. Monoclonal antibodies to T4 labeled with a chemiluminescent acridinium ester are used. Serum samples are incubated with the labeled antibodies and a thyroxin-rabbit immunoglobulin conjugate, then reacted with magnetizable particles containing sheep anti-rabbit immunoglobulin. The total reaction time is 40 min. The chemiluminescence intensity of the solid-phase immune complexes is inversely proportional to the concentration of T4 in the sample. The sensitivity of the assay is 1 nmol/L, and the working range of 20-190 nmol/L is characterized by CVs less than or equal to 10%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-step, labeled-antibody assay for measuring free thyroxin. I. Assay development and validation.

We describe a one-step, labeled-antibody radioassay for measuring free thyroxin (FT4) in serum or plasma, based on a novel principle. FT4 in the sample competes with a gross molar excess (over antibody) of a cross-reactant (L-triiodothyronine, T3), chemically coupled to magnetizable polymer particles, for binding to avid 125l-labeled monoclonal anti-thyroxin antibodies. As in conventional immun...

متن کامل

Effect of albumin concentration on the assay of serum free thyroxin by equilibrium radioimmunoassay with labeled thyroxin analog (Amerlex Free T4).

Serum free thyroxin (FT4) in normal nonpregnant and pregnant subjects was measured by radioimmunoassay (RIA) with Amerlex FT4 RIA (Amersham International) and LiquiSol FT4 RIA (Damon Diagnostics) kits. Amerlex FT4 values in serum from pregnant women were lower than those in serum from nonpregnant women, but LiquiSol FT4 values were similar in serum from both groups. Amerlex FT4 values were dire...

متن کامل

High-throughput automated luminescent magnetic particle-based immunoassay to monitor human exposure to pyrethroid insecticides.

We have developed a sensitive, automated, competitive chemiluminescent immunoassay for the detection of 3-phenoxybenzoic acid (3-PBA), a metabolite common to many pyrethroid insecticides. The system uses a competitive hapten-protein conjugate that has been labeled with an acridinium ester as the chemiluminescent probe and secondary antibody-coated paramagnetic particles for the separation. Afte...

متن کامل

Cortisol directly determined in serum by fluoroimmunoassay with magnetizable solid phase.

We developed a direct fluoroimmunoassay for cortisol in serum. This method involves cortisol labeled at the 3 position with fluorescein, and antibodies to cortisol coupled to magnetizable cellulose/iron oxide particles. Sodium salicylate is used as a blocking agent to prevent interference from endogenous binding proteins in serum. Serum sample and labeled cortisol are incubated with the antibod...

متن کامل

Preparation of an artificial matrix to replace human standards of prostate specific antigen IRMA assay kit [Persian]

  Introduction: Prostate specific antigen (PSA) is one of the most sensitive markers for diagnosis of prostate cancer. Immunoradiometric kit (IRMA) is a common and sensitive method for determination of PSA in clinical laboratories. This kit has four major components: solid phase coated with monocolonal antibody, pair antibody labelled with I-125, series of standards i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 1986