A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems
نویسندگان
چکیده
The recommended methods to test the performance of computed radiography (CR) systems have been established by The American Association of Physicists in Medicine, Report No. 93, “Acceptance Testing and Quality Control of Photostimulable Storage Phosphor Imaging Systems”. The quality assurance tests are categorized by how frequently they need to be performed. Quality assurance of CR systems is the responsibility of the facility that performs the exam and is governed by the state in which the facility is located. For Example, the New York State Department of Health has established a guide which lists the tests that a CR facility must perform for quality assurance. This study aims at educating the reader about the new quality assurance requirements defined by the state. It further demonstrates an easy to use software tool, henceforth referred to as the Digital Physicist, developed to aid a radiologic facility in conforming with state guidelines and monitoring quality assurance of CR/DR imaging systems. The Digital Physicist provides a vendor independent procedure for quality assurance of CR/DR systems. Further it, generates a PDF report with a brief description of these tests and the obtained results.
منابع مشابه
Quality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کاملThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
متن کاملEvaluation of Doses and Image Quality in Mammography with Screen-Film, CR, and DR Detectors – Application of the ACR Phantom
BACKGROUND Different methods of image quality evaluation are routinely used for analogue and digital mammography systems in Poland. In the present study, image quality for several screen-film (SF), computed radiography (CR), and fully digital (DR) mammography systems was compared directly with the use of the ACR mammography accreditation phantom. MATERIAL/METHODS Image quality and mean glandu...
متن کاملImage quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study
Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...
متن کاملThe characteristics of Fuji IP Cassette Type PII and application for radiotherapy quality assurance tests and portal imaging
The advancement of digital imaging has prompted more medical institutions to go filmless. The computed radiography (CR) system is becoming an important tool not only in diagnostic imaging, but also in radiation oncology. A new CR system that was specially designed for the use in radiation oncology, Fuji IP cassette type PII has been introduced to the market in the middle of year 2006. This proj...
متن کامل