Prediction of pregnancy complication occurrence using fetal cardiac output assessments made by ultrasonography at 20 to 24 weeks of gestation

نویسندگان

  • Ji Yeon Lee
  • Young Li Kim
  • Ji Eun Jeong
  • Jun Woo Ahn
چکیده

OBJECTIVE To evaluate the importance of assessment of fetal cardiac output (CO) for the prediction of complications of pregnancy. METHODS We evaluated 65 fetuses and all of them had a fetal cardiac scan at 20 to 24 weeks of pregnancy. To measure CO, diameters (d) of the left right ventricle outflow tract were measured just above the valves. Each left CO (LCO) and right CO (RCO) was derived using the following equation: CO = velocity time integral × π × d2/4 × heart rate. Pregnancy complications included gestational hypertensive disorders, fetal growth restriction (FGR) and preterm birth (PTB) caused from preterm labor or preterm premature rupture of membrane (PPROM). RESULTS There were 23 cases with one more pregnancy complication (FGR, 9; gestational hypertensive disorders, 8; PTB caused from PTB or PPROM, 12). The LCO was lower in complication group than in normal group (88±53 vs. 117±48 mL/min, P=0.028). The RCO to the LCO ratio (RCO/LCO) was higher in complication group (2.43±1.69 vs. 1.48±0.81, P=0.001). Regression analysis demonstrated that RCO/LCO was a significant predictor of pregnancy complication; Odds ratio was 7.76 (95% CI, 1.15 to 52.21; P=0.029). The area under the receiver-operating characteristic curve for prediction of pregnancy complications from LCO was 0.71. The diagnostic cut-off value of LCO was 80 mL/min. The area under the receiver-operating characteristic curve from RCO/LCO was 0.68 and cut-off value was 1.41. CONCLUSION This study demonstrated that pregnancy complications can be suspected based on fetal CO assessments at a GA of 20 to 24 weeks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Prolonged Pregnancy in Nulliparous Women by Transvaginal Ultrasonographic Measurement of Cervical Length at 20-24 Weeks and 37 Weeks

This study was done to evaluate transvaginal ultrasonographic measurement of cervical length at 20 to 24 weeks and 37 weeks as a predictor of prolonged pregnancy (defined as a pregnancy that extended beyond 41+2 weeks of gestation [289 days]) in nulliparous women. This prospective observational study enrolled 149 consecutive nulliparous women with singleton gestation at 37 weeks. Cervical lengt...

متن کامل

I-44: Increased Nuchal Translucency at 11-14 Weeks of Gestation As A Marker for Adverse Pregnancy Outcomes

Background: To evaluate the association of increased fetal nuchal translucency( NT) and adverse pregnancy outcomes. Materials and Methods: In a prospective study, 2221 women who were conceived after Assisted Conception were investigated by sonography independent of multiplicity between 11 and 13 weeks' gestation. We performed 2899 NT examinations during the study period(21 March 2010 to 21...

متن کامل

Prediction of adverse pregnancy outcomes using uterine artery Doppler imaging at 22-24 weeks of pregnancy: A North Indian experience

OBJECTIVE The aim of this study was to assess the predictive value of uterine artery Doppler imaging at 22-24 weeks of gestation for adverse pregnancy outcomes. MATERIALS AND METHODS This was a prospective study in which uterine artery Doppler was performed at 22-24 weeks of gestation in 165 pregnant women with singleton pregnancies. A pulsatility index (PI) more than 1.45 or bilateral uterin...

متن کامل

Fetal cardiac output and ejection fraction by spatio-temporal image correlation (STIC): comparison between male and female fetuses.

OBJECTIVE To compare the cardiac output (CO) and ejection fraction (EF) of the heart of male and female fetuses obtained by 3D-ultrasonography using spatio-temporal image correlation (STIC). METHODS We conducted a cross-sectional study with 216 normal fetuses, between 20 and 34 weeks of gestation, 108 male and 108 female. Ventricular volumes at the end of systole and diastole were obtained by...

متن کامل

Heart stroke volume and cardiac output by four-dimensional ultrasound in normal fetuses.

OBJECTIVE To establish reference intervals for fetal heart stroke volume and cardiac output with gestation. METHODS Fetal heart ventricular volumes were measured using the four-dimensional (4D) spatiotemporal imaging correlation (STIC) ultrasound technique in 140 normal singleton pregnancies at 12-34 weeks' gestation. The Virtual Organ Computer-aided AnaLysis (VOCAL) technique was used to obt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 60  شماره 

صفحات  -

تاریخ انتشار 2017