Effect of tunnel length on infection rate in patients with external ventricular drain.

نویسندگان

  • Mirza Faisal Ahmed Rafiq
  • Noor Ahmed
  • Shafqut Ali
چکیده

BACKGROUND External ventricular drain involves catheter placement in ventricles of brain. It is used for various purposes. Basic theme is to drain cerebrospinal fluid so as to control intracranial pressure. This study was carried out to see the effect of tunnel length on rate of infection. METHODS This was a cross-sectional study carried out in Department of Neurosurgery, Pakistan Institute of Medical Sciences, Islamabad during 14 months from 1st December 2008 to 31 January 2010. External ventricular drain was placed in admitted patients after meticulous aseptic technique in operation theatre at right Kocher's point. It was carried out through a scalp tunnel and was connected to drainage bag through a drip set. Both long (> 5 Cm) and short (< 5 Cm) tunnels were randomly made. Infection rate was estimated in patients who had change of cerebrospinal fluid colour or developed fever (as per protocol to have minimum handling of drain). All patients received prophylactic Ceftriaxone. RESULTS Among 76 patients long tunnel was made in 44 (57.9%) and short in 32 (42.1%). Three patients (3.9%) with long tunnel while 6 (7.9%) patients with short tunnel had infection. The overall infection was in 9 (11.8%) patients. CONCLUSION External ventricular drain tunnel length strongly influences the rate of infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Switching Performance of Nanotube Core-Shell Heterojunction Electrically Doped Junctionless Tunnel Field Effect Transistor

Abstract: In this paper, a novel tunnel field effect transistor (TFET) is introduced, thatdue to its superior gate controllability, can be considered as a promising candidate forthe conventional TFET. The proposed electrically doped heterojunction TFET(EDHJTFET) has a 3D core-shell nanotube structure with external and internal gatessurrounding the channel that employs el...

متن کامل

Improved drain current characteristics of tunnel field effect transistor with heterodielectric stacked structure

In this paper, we proposed a 2-D analytical model for electrical characteristics such as surface potential, electric field and drain current of Silicon-on-Insulator Tunnel Field Effect Transistor (SOI TFETs) with a SiO2/High-k stacked gate-oxide structure. By using superposition principle with suitable boundary conditions, the Poisson’s equation has been solved to model the channel r...

متن کامل

Prognostic value of right ventricular myocardial performance index in patients undergoing coronary artery bypass surgery

 Abstract Background: Right ventricular myocardial performance index (RVMPI) is a Doppler–derived parameter of non-geometrical ventricular function that measures both systolic and diastolic functions of the right ventricle. The aim of this study is to compare prognostic value of RVMPI with global RV function in patients undergoing Coronary Artery Bypass Graft (CABG). Methods: In a longitudinal ...

متن کامل

External ventricular drain infections: successful implementation of strategies to reduce infection rate.

INTRODUCTION External ventricular drain (EVD) infections can cause serious complications. We performed an audit of EVD infections within our neurosurgical unit. Through this study, we aimed to reduce the incidence of external ventricular drain-related infection, including ventriculities in neurosurgical patients. METHODS We conducted an audit of the EVD infections in our institution observed ...

متن کامل

Failure of regular external ventricular drain exchange to reduce cerebrospinal fluid infection: result of a randomised controlled trial.

BACKGROUND It is controversial whether regular changes of external ventricular drains can reduce cerebrospinal fluid (CSF) infection. OBJECTIVE To carry out a randomised controlled clinical trial over a two year period to determine whether a regular change of ventricular catheter every five days could reduce CSF infection and improve outcome. METHODS 103 patients requiring external ventricu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Ayub Medical College, Abbottabad : JAMC

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2011