The relative accuracy of simultaneous same arm, simultaneous opposite arm and sequential same arm measurements in the validation of automated blood pressure measuring devices.

نویسندگان

  • N Atkins
  • F Mee
  • K O'Malley
  • E O'Brien
چکیده

With the increasing demand for accurate BP measuring devices there comes also the need for validation. Most validation procedures assess the accuracy of a test device against a known standard, most commonly a mercury sphygmomanometer. The best method for assessing device accuracy is to measure BP simultaneously in the same arm with the test device and a mercury sphygmomanometer. This is not always possible because the deflation mechanism of the test device interferes with the ability of an observer to auscultate the Korotkov sounds accurately. In this study a mathematical method of sequential comparison between the test device and a mercury standard in the same arm is described which is almost as accurate as simultaneous measurement in the same arm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of blood pressure measurements on the upper and lower extremities during spinal anesthesia

Introduction: During spinal anesthesia, measurement of blood pressure is often obtained by an indirect method using an inflatable cuff on the upper arm. The relationship between the blood pressure measurements at the two sites in patients undergoing spinal anesthesia is unclear. This study was designed to evaluate the difference observed in systolic blood pressure (SBP) taken from the upp...

متن کامل

Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

OBJECT Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The fact...

متن کامل

Measuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors?

OBJECTIVES To compare the agreement between conventional measurement of blood pressure and measurements obtained using two automated devices; and to compare how comfortable each of the three methods of measurement were for patients. METHODS Blood pressure measurements and patient comfort scores were recorded using three different devices in 125-surgery and 40-community patients. The devices u...

متن کامل

The normal range for inter-arm differences in blood pressure.

OBJECTIVE to establish the mean and normal range for the difference in simultaneous systolic and diastolic blood pressure measurements between the right and left arm. SUBJECTS 462 subjects, age range 20-89 years, in sinus rhythm and with no history of stroke, 98 of whom had a history of cardiovascular disease or were taking vasoactive medication. METHODS four simultaneous recordings of bloo...

متن کامل

تأثیر وضعیت‌های مختلف قرارگیری اندام‌های بیماران مبتلا به پرفشاری خون بر میزان فشارخون آنان

Introduction: In hypertensive patients M position (sitting, right arm at the level of heart and both plantar surface of foots on the floor) is the standard position for measurment of blood pressure since it reveals the “true” pressure. Materials and Methods: It is a quaziexperimental study that compares effect of different positions of limbs on blood pressure of hypertensive patients. The sampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of human hypertension

دوره 4 6  شماره 

صفحات  -

تاریخ انتشار 1990