A comprehensive evaluation of adaptive daily planning for cervical cancer HDR brachytherapy

نویسندگان

  • Rebecca Meerschaert
  • Adrian Nalichowski
  • Jay Burmeister
  • Arun Paul
  • Steven Miller
  • Zhenghui Hu
  • Ling Zhuang
چکیده

The purpose of this study was to evaluate adaptive daily planning for cervi-cal cancer patients who underwent high-dose-rate intracavitary brachytherapy (HDR-BT) using comprehensive interfractional organ motion measurements. This study included 22 cervical cancer patients who underwent 5 fractions of HDR-BT. Regions of interest (ROIs) including high-risk clinical tumor volume (HR-CTV) and organs at risk (OARs) were manually contoured on daily CT images. All patients were clinically treated with adaptive daily plans (ADP), which involved ROI delineation and dose optimization at each treatment fraction. Single treatment plans (SP) were retrospectively generated by applying the first treatment fraction's dwell times adjusted for decay and dwell positions of the applicator to subsequent treatment fractions. Various existing similarity metrics were calculated for the ROIs to quantify interfractional organ variations. A novel similarity (JRARM) score was established, which combined both volumetric overlap metrics (DSC, JSC, and RVD) and distance metrics (ASD, MSD, and RMSD). Linear regression was performed to determine a relationship between interfractional organ varia-tions of various similarity metrics and D2cc variations from both plans. Wilcoxon signed-rank tests were used to assess ADP and SP by comparing EQD2 D2cc (α/β = 3) for OARs. For interfractional organ variations, the sigmoid demonstrated the greatest variations based on the JRARM, DSC, and RMSD metrics. Comparisons between paired ROIs showed differences in metrics at each treatment fraction. RVD, MSD, and RMSD were found to be significantly correlated to D2cc varia-tions for bladder and sigmoid. The comparison between plans found ADP provided lower EQD2 D2cc of OARs than SP. Specifically, the sigmoid demonstrated sta-tistically significant dose variations (p = 0.015). Substantial interfractional organ motion occurs during HDR-BT based on comprehensive measurements and may significantly affect D2cc of OARs. Adaptive daily planning provides improved dose sparing for OARs compared to single planning with the extent of sparing being different among OARs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector

Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...

متن کامل

Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans

Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...

متن کامل

Accuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

متن کامل

Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016