A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures

نویسندگان

  • Karim Ghazikhanlou Sani
  • Mahmoodreza Jafari
  • Nima Rostampoor
چکیده

The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were taken from other views (predominantly oblique views), making a total number of 128 radiographs. Paired radiographs, taken from the same areas, were compared by two radiologists in terms of image visual sharpness, presence of bony fractures, and soft tissue injuries. The surface dose received by patients in the two systems was also compared. The radiographs taken by mammography film-screen had a statistically better visual sharpness compared to those taken by the standard film-screen system. However, there was no statistically significant difference between the diagnostic accuracy of the two systems. Mammography film-screen was able to detect only one out of 57 lesions, whereas standard film-screen system did not detec any lesion. The surface dose received by patients in mammography film-screen was higher than that in standard film-screen system. The findings of the present study suggest that mammography film-screen may be recommended as a diagnostic tool for the detection of small fractures of tinny parts of body such as fingers, hand or foot. They also suggest that mammography film-screen has no advantage over standard film-screen for radiography of thick body parts such as neck and knee.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures

The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...

متن کامل

Improved fracture detection using the mammographic film-screen combination

AIM The single emulsion or single screen system is usually reserved for mammography since its use in general radiography is limited. The purpose of this study is to compare the mammographic film-screen combination (MFC) and the standard film-screen combination (SFC) in terms of fracture and soft tissue injuries detection. PATIENTS, METHODS AND MATERIALS: In this prospective study, 41 patients f...

متن کامل

توموگرافی خطی با فیلم و Photostimulable Phosphor Plate در طرح درمان ایمپلنت در مندیبل

Background and Aims: Radiographic examination prior to implant placement is often complemented with tomography for location of vital anatomic structures and evaluation of bone volume. The aim of this study was to evaluate the accuracy of Photostimulable Phosphor Plate system with that of conventional film-screen in mandibular pre-implant linear tomography Materials and Methods: In this test eva...

متن کامل

Mammographic microcalcifications: detection with xerography, screen-film, and digitized film display.

Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray ...

متن کامل

Performance tests for mammographic film-screen combinations: use of absolute techniques.

PURPOSE A performance comparison of film-screen combination used in mammography was conducted using conventional and new techniques. MATERIALS AND METHODS The performance of 30 mammographic film-screen combinations was evaluated by sensitometry, and the total performance was determined using phantom measurements. Quantum detection and light emission efficiency of the screens were also measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2011