Simplified protocol of nuchal translucency measurement: Is it still effective?

نویسندگان

  • Sun Min Kim
  • Jong Kwan Jun
چکیده

OBJECTIVE Nuchal translucency (NT) is the most powerful screening tool for Down syndrome and congenital cardiac anomaly, therefore strict guidelines were established to get accurate NT values. However, to stick to the guideline in all pregnant women is time-consuming and superfluous in majority of low risk population. We undertook this study to investigate whether the simplified protocol enables to select low risk group and is effective in them even if we skip the suggested NT measurement. METHODS NT and crown-rump length (CRL) were measured prospectively. First, CRL was measured in the ordinary view that was mid-sagittal section of fetus in neutral position, and NT was measured at the same frozen screen (first measured value, 1MV). Then, NT was measured again according to the Fetal Medicine Foundation (FMF) guideline (second measured value, 2MV). RESULTS There was good correlation between 1MV and 2MV in each case (r = 0.83, P < 0.001). All of the NT values over the 95th percentile in 2MV also belonged to over the 95th percentile in 1MV. NT value of 2 mm in 1MV could be used as a cut-off to obtain over the 95th percentile 2MV by receiver operating characteristic curve (sensitivity 100%, specificity 80.5%). The proportion of 1MV ≥ 2 mm was only 23.8% of all cases, namely we had only to measure 2MV in 23.8% patients. Every 95th percentile or more 2MV could be detected with this simplified protocol. CONCLUSION If NT is less than 2 mm at ordinary CRL view, we may skip suggested NT measurement according to FMF guideline.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Nuchal Translucency Measuremen in First Trimester Pregnancy

Background A significant number of pregnancies, particularly in women with previous histories of infertility, are associated with fetal abnormalities. Methods such as the nuchal translucency (NT) measurement enable us to identify more pregnancies with chromosomal abnormalities. MaterialsAndMethods This analytic cross-sectional study was performed in 446 pregnant women at 11-14 weeks gestation, ...

متن کامل

Nuchal translucency and first trimester biochemical markers for down syndrome screening: a cost-effectiveness analysis.

OBJECTIVE The purpose of this study was to perform a cost-effectiveness analysis that compared the first- and second- trimester screening tools for Down syndrome. STUDY DESIGN A decision tree was designed that compared four possible screens for Down syndrome: (1) current second- trimester expanded maternal serum alpha-fetoprotein test (AFP), (2) first-trimester nuchal translucency screen, (3)...

متن کامل

Nuchal translucency and nasal bone for trisomy 21 screening: single center experience.

AIM To evaluate the feasibility and diagnostic accuracy of fetal nuchal translucency and nasal bone assessment at 11-14 weeks for screening of trisomy 21 at a single center. METHODS Nuchal translucency measurement and nasal bone evaluation in relation to the fetal karyotype for singleton fetuses were retrospectively assessed at the Ospedale Microcitemico, Cagliari, Italy, in a three-year peri...

متن کامل

Measurement of Nuchal Translucency Thickness for Detection of Chromosomal Abnormalities using First Trimester Ultrasound Fetal Images

The Nuchal Translucency thickness measurement is made to identify the Down Syndrome in screening first trimester fetus and presented in this paper. The mean shift analysis and canny operators are utilized for segmenting the nuchal translucency region and the exact thickness has been estimated using Blob analysis. It is observed from the results that the fetus in the 14th week of Gestation is ex...

متن کامل

Effects of period of gestation and position of fetal neck on nuchal translucency measurement.

OBJECTIVE The aim of this study was to determine the effects of period of gestation and position of fetal neck on nuchal translucency measurement. MATERIALS AND METHODS Nuchal translucency was measured in the mid-sagittal plane, with the fetal neck in the flexed, neutral, and extended positions in 100 pregnant women between 11 and 13(+6) weeks. Mean nuchal translucency measurements at differe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2013