Photoelastic stress analysis in mandibular bone surrounding bar-clip overdenture implants.

نویسندگان

  • Mônica Nogueira Pigozzo
  • Dalva Cruz Laganá
  • Newton Sesma
  • Glaís Ferrari de Souza
  • Alvaro Luiz Ichi
چکیده

The aim of this in vitro study was to evaluate, using the photoelastic analysis method, the stress distribution in mandibular bone surrounding a bar-clip overdenture when 2 implant angulations were simulated. Two mandibular photoelastic models were manufactured, with 2 implants embedded in the interforaminal region: model 1-PAPI, a photoelastic analysis model with parallel implants; and model 2-PAAI, a photoelastic analysis model with angled implants. A bar-clip retention system and an overdenture were positioned over the implants, and loads of 1.0, 2.0 and 3.0 bars were applied. The resultant stresses that developed in the supporting structure were photoelastically monitored and were recorded photographically. The results showed that there were no similarities in the areas of stress among the photoelastic resin models when the angulation of the implants was evaluated. Model 1-PAPI presented a higher stress concentration at the implant apex, while in model 2-PAAI, there were higher stress concentrations on the mesial and distal implant faces. Within the limitations of this study, it was concluded that the PAPI photoelastic model demonstrated better stress transfer compared to the PAAI model, since the forces oriented along the axis were better absorbed by the bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoelastic Stress Analysis Surrounding Implant-Supported Prosthesis and Alveolar Ridge on Mandibular Overdentures

The purpose of this research was to evaluate the maximum stress around osseointegrated implants and alveolar ridge, in a mandible with left partial resection through a photoelastic mandibular model. The first group consisted of two implants: traditional model (T), implants placed in the position of both canines; fulcrum model (F), implants placed in the position of left canine CL and right late...

متن کامل

Biomechanical Analysis of Implant Assisted-Overdentures with Variations in the Attachments Systems

The aim of this study was to assess the stress patterns on the peri-implant zone and residual alveolar ridge in different overdenture attachment system designs by the photoelasticity method. Four attachments systems were tested: O-ring, ERA, Bar-clip, and Bar-clip/O-ring association. The prostheses were loaded with 100 N in five pre-determined points and the photoelastic model was evaluated by ...

متن کامل

Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants

OBJECTIVE There is no definitive study comparing stress distribution around two versus three implants in implant-retained overdentures with different cantilever length. The purpose of this finite element study was to evaluate stress pattern around the implants of the 2 or 3 implant- supported mandibular overdenture with different cantilevered length. MATERIALS AND METHODS The models used in t...

متن کامل

Mandibular overdentures retained by two implants: 10-year results from a crossover clinical trial comparing ball-socket and bar-clip attachments.

PURPOSE The aim of this study was to evaluate patient satisfaction and clinical and prosthetic outcomes of two-implant mandibular overdenture treatment with different attachment types after 10 years of function. MATERIALS AND METHODS In a crossover clinical trial, 18 edentulous subjects with complaints regarding their mandibular dentures received two implants and a new denture with magnet, ba...

متن کامل

Influence of attachment systems on load transfer of an implant-assisted maxillary overdenture.

PURPOSE This photoelastic study compared the load transfer characteristics of 2 retention mechanisms in an implant-assisted overdenture prosthesis. MATERIALS AND METHODS Four implants were incorporated into a photoelastic model of a moderately resorbed edentulous human maxilla. Two retention mechanisms were studied by changing components on the same model and the palateless overdenture. The r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2014