Femoral tunnel widening after quadrupled hamstring anterior cruciate ligament reconstruction.

نویسندگان

  • Philip Cheung
  • Wai-lam Chan
  • Chi-hung Yen
  • Sze-chung Cheng
  • Siu-bon Woo
  • Tsz-kau Wong
  • Wing-cheung Wong
چکیده

PURPOSE To evaluate the extent of femoral tunnel widening after quadrupled hamstring anterior cruciate ligament reconstruction using femoral cross pin fixation in contrast to bioabsorbable screw fixation augmented with Endopearl. METHODS 16 patients underwent cross pin femoral fixation and the next 15 underwent bioabsorbable screw fixation augmented with Endopearl. The patients were evaluated radiographically for femoral tunnel widening. Standard posteroanterior radiographs of the knee in full extension were taken at postoperative year 2 and 5. The tunnel width was measured at the opening, the widest and the most proximal parts of the femoral tunnel. RESULTS In the femoral cross pin and bioabsorbable screw fixations, the mean femoral tunnel sizes were 7.6 and 8.0 mm, respectively. The overall mean tunnel widening at all measured sites were 2.7 and 1.8 mm at the 2-year follow-up and were 2.5 and 1.8 mm at the 5-year follow-up, respectively. The femoral tunnel widening was greater in the cross pin than the bioabsorbable screw group, but only the difference in the most proximal part was significant (p=0.01 at year 2 and p<0.001 at year 5). CONCLUSION Femoral tunnel widening was greater in femoral cross pin fixation, probably related to the windshield-wiper and bungee-cord effects. It usually occurred in the first 2 years after the operation and remained static thereafter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic reconstruction of the anterior cruciate ligament with quadrupled hamstring tendons. A correlation between MRI changes and restored stability of the knee.

A total of 30 patients who underwent endoscopic reconstruction of the anterior cruciate ligament using quadrupled hamstring tendons, through a single drill hole in the femur, had MRI 24 to 28 months after operation. In 18 patients the scans revealed that both the anterior and posterior portions of the graft ran in parallel from the inside of the femoral to the tibial tunnel. In 12, the posterio...

متن کامل

Biomechanical comparison of single-tunnel-double-bundle and single-bundle anterior cruciate ligament reconstructions.

BACKGROUND Anatomic double-bundle reconstruction has been thought to better simulate the anterior cruciate ligament anatomy. It is, however, a technically challenging procedure, associated with longer operation time and higher cost. HYPOTHESIS Double-bundle anterior cruciate ligament reconstruction using a single femoral and tibial tunnel can closely reproduce intact knee kinematics. STUDY ...

متن کامل

Bone Tunnel Impaction Reduced the Tibial Tunnel Enlargement

The purpose of this study was to investigate whether the bone tunnel impaction technique performed by dilators could dwindle the tibial tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with hamstring tendon using both extracortical suspensory fixation devices at femoral and tibial site. Thirty-one consecutive patients undergoing primary ACL reconstruction with the hamstr...

متن کامل

Cross Pins versus Endobutton Femoral Fixation in Hamstring Anterior Cruciate Ligament Reconstruction: Minimum 4-Year Follow-Up

PURPOSE We aimed to compare cross-pin fixation and Endobutton femoral fixation for hamstring anterior cruciate ligament (ACL) reconstruction with respect to clinical and radiographic results, including tunnel widening and the progression of knee osteoarthritis (OA). MATERIALS AND METHODS Between August 2002 and August 2005, 126 autogenous hamstring ACL reconstructions were performed using eit...

متن کامل

Effect of PEEK polymer on tunnel widening after hamstring ACL reconstruction.

The purpose of this study was to evaluate the effect of the AperFix device (Cayenne Medical, Inc, Scottsdale, Arizona), composed of polyetheretherketone (PEEK) polymer, on tunnel widening after hamstring anterior cruciate ligament (ACL) reconstruction as compared with 2 other fixation devices: the TransFix (Arthrex, Inc, Naples, Florida) and the EndoButton (Smith & Nephew Endoscopy, Mansfield, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2010