Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-up

نویسندگان

  • Kazuaki Nakauchi
  • Hidenori Mito
  • Osamu Mimura
چکیده

BACKGROUND The frontalis suspension technique is the surgical method of choice in patients with ptosis and a levator function of 4 mm or less. Several types of materials have been used, including Gore-Tex(®), which has been used successfully as a frontalis sling material since 1986. Recently, a Gore-Tex sheet (wider than a sling or strip) suspension was reported. This paper reports the results of 27 eyes from 20 patients with congenital ptosis treated using the frontalis suspension technique with the newly developed Gore-Tex Most Versatile Patch (MVP) sheet. METHODS All patients underwent surgery between April 2007 and September 2011 and were followed up for at least one year. The average follow-up duration was 18 months, with a range of 12-36 months. The average patient age was 45 (5-85) years, and the group included 11 males and nine females. Thirteen cases demonstrated ptosis in one eye, and seven cases involved both eyes. The patients were divided by age into a younger group and an older group. All ptosis procedures were performed using the Gore-Tex MVP sheet. The implant was normally 7 mm wide for adults and 5 mm wide for children. The implantation method was the same as that used for the sheet shape fascia. RESULTS In all patients, satisfactory functional results were observed at the 6-month follow-up examination. Eyelid opening heights were also obtained. The average marginal reflex distance (MRD) was -0.5 mm preoperatively, which improved to +1.9 mm after surgery. After one year, average MRD was +1.6 mm. MRD attenuation was more frequent in the younger group. There were no cases requiring redo surgery and only one case of exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nasal augmentation using Gore-Tex. A 10-year experience.

OBJECTIVE To determine on an ongoing basis the safety and efficacy of expanded polytetrafluoroethylene (Gore-Tex soft tissue patch and preformed nasal implants) as an implant in rhinoplasty. DESIGN A retrospective study of 309 consecutive patients who underwent rhinoplasty, including augmentation with Gore-Tex, during a 10-year period. SETTING Two major academic medical centers and 2 privat...

متن کامل

Clinical trial comparing autogenous fascia lata sling and Gore-Tex suspension in bilateral congenital ptosis

PURPOSE To study the effect of autogenous fascia lata sling (AFLS) versus Gore-Tex suspension (GTS) regarding the functional and aesthetic outcomes in patients with bilateral congenital ptosis. PATIENTS AND METHODS A prospective comparative randomized single-center study enrolled 110 patients with bilateral congenital ptosis. One group (n=55) underwent AFLS and the second group (n=55) underwe...

متن کامل

Infected ptosis surgery – a rare complication from a multidrug-resistant organism

A 7-year-old boy had a case of congenital ptosis of the right eye and has undergone frontalis sling surgery using Gore-tex material. There was no intraoperative or immediate postoperative complication. However, the patient defaulted his follow-up and presented with right eye preseptal abscess secondary to infected surgical wound 1 month after surgery. He was treated with multiple antibiotics an...

متن کامل

Expanded polytetrafluoroethylene implants in rhinoplasty: literature review, operative techniques, and outcome.

Gore-Tex, a form of expanded polytetrafluoroethylene (ePTFE), over the past 30 years has attracted much attention as an alloplast for use in rhinoplasty, both from advocates and opponents of its use. It has many desirable traits as an alloplast implant, but many surgeons harbor hesitation and reluctance for alloplast use in rhinoplasty based on historical data of previous nasal implants. Only w...

متن کامل

ارزیابی و مقایسه عوارض وتمامیت فیستول شریانی- وریدی باگرافت گورتکس 6 و 8 میلی‌متری در اندام فوقانی و مقایسه آن‌ها با گرافت گورتکس 8 میلی‌متری اندام تحتانی در یک سال اول پس از عمل

Background & Aims: This study was done in hem dialysis patients who referred to Imam Khomeini hospital of Urmia for insertion of arterial -venous fistula with Gore-tex, in whom there was not possibility of natural fistula. Objectives were assessment and comparison of complications and patency of arterial-venous fistulas was done with 6 and 8 mm Gore-tex graft in the upper limb and comparison of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013