Postcollection synthesis of ethyl glucuronide by bacteria in urine may cause false identification of alcohol consumption.

نویسندگان

  • Anders Helander
  • Ingrid Olsson
  • Helen Dahl
چکیده

BACKGROUND Ethyl glucuronide (EtG) is a minor ethanol metabolite used as a specific marker to document recent alcohol consumption; confirm abstinence in treatment programs, workplaces, and schools; and provide legal proof of drinking. This study examined if bacterial pathogens in urine may enable postsampling synthesis of EtG and ethyl sulfate (EtS) from ethanol, leading to clinical false-positive results. METHODS Urine specimens with confirmed growth of Escherichia coli, Klebsiella pneumoniae, or Enterobacter cloacae were stored at room temperature in the presence of ethanol. Ethanol was either added to the samples or generated by inoculation with the fermenting yeast species Candida albicans and glucose as substrate. EtG and EtS were measured by LC-MS. RESULTS High concentrations of EtG (24-h range 0.5-17.6 mg/L) were produced during storage in 35% of E. coli-infected urines containing ethanol. In some specimens that were initially EtG positive because of recent alcohol consumption, EtG was also sensitive to degradation by bacterial hydrolysis. In contrast, EtS was completely stable under these conditions. CONCLUSIONS The presence of EtG in urine is not a unique indicator of recent drinking, but might originate from postcollection synthesis if specimens are infected with E. coli and contain ethanol. Given the associated risks for false identification of alcohol consumption and false-negative EtG results due to bacterial degradation, we recommend that measurement of EtG be combined with EtS, or in the future possibly replaced by EtS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postcollection Synthesis of Ethyl Glucuronide by Bacte- ria in Urine May Cause False Identification of Alcohol

ria in Urine May Cause False Identification of Alcohol Consumption (Department of Clinical Neuroscience, Karolinska Institute and Karolinska University Hospital, Stockholm, Sweden; * address correspondence to this author at: Alcohol Laboratory, L7:03, Karolinska University Hospital Solna, SE-171 76 Stockholm, Sweden; fax 46-8-51771532, e-mail [email protected]) Anders Helander,* Ingrid Olss...

متن کامل

Preliminary immunochemical test for the determination of ethyl glucuronide in serum and urine: comparison of screening method results with gas chromatography-mass spectrometry.

Ethyl glucuronide is a highly specific metabolite of ethanol that is formed by enzymatic conjugation of ethanol with glucuronic acid. Because of its suitability as a marker of excessive alcohol consumption in serum with low blood-alcohol concentration and as a consumption marker in serum and urine, especially after the breakdown of ethanol, demand exists for a simple and fast analytical procedu...

متن کامل

Sensitivity of commercial ethyl glucuronide (ETG) testing in screening for alcohol abstinence.

The '80 h Ethyl Glucuronide (EtG) test' has become an idiom of the alcohol testing community, a review of the literature shows this window of detection applies only to extreme cases. EtG testing is becoming more common as a method to test for alcohol consumption in individuals who have been ordered to abstain from alcohol consumption. We tested 19 subjects using commercially available EtG kits....

متن کامل

Comparison of ethyl glucuronide and carbohydrate-deficient transferrin in different body fluids for post-mortem identification of alcohol use.

AIMS Alcohol abuse is a major risk factor for premature death. Confirming the role of alcohol consumption in cause-of-death investigations has, however, remained difficult, due to lack of reliable biomarkers. METHODS We compared ethyl glucuronide (EtG) and carbohydrate-deficient transferrin (CDT) assays from serum, urine, cerebrospinal fluid and vitreous humor in a forensic autopsy population...

متن کامل

Urinary tract infection: a risk factor for false-negative urinary ethyl glucuronide but not ethyl sulfate in the detection of recent alcohol consumption.

tive Urinary Ethyl Glucuronide but Not Ethyl Sulfate in the Detection of Recent Alcohol Consumption, Anders Helander and Helen Dahl (Department of Clinical Neuroscience, Karolinska Institutet and University Hospital, Stockholm, Sweden; * address correspondence to this author at: Alcohol Laboratory, L7:03, Karolinska University Hospital Solna, SE-171 76 Stockholm, Sweden; fax 46-8-51771532, e-ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 53 10  شماره 

صفحات  -

تاریخ انتشار 2007