Technetium-99m radiopharmaceutical preparation problems: 12 years of experience.
نویسنده
چکیده
OBJECTIVE Chemical reactions involved in preparing 99mTc radiopharmaceuticals occasionally result in products of substandard purity. A retrospective examination of preparation problems that occurred in the author's institution was conducted to better define the incidence, recognize patterns and identify causes of substandard 99mTc radiopharmaceutical products. METHODS All 99mTc radiopharmaceutical preparation and quality control testing records for the years 1986-1997 were reviewed, and preparation factors associated with substandard products were identified and examined. RESULTS Fifty of 20,972 (0.2%) 99mTc products had substandard radiochemical purity; none were administered to patients. Twenty-eight of the 50 substandard products (56%) involved macroaggregated albumin with the remainder divided among in vitro red blood cells, exametazime, disofenin, sestamibi, mertiatide and sulfur colloid. Thirty-three of the 50 (66%) involved 99mTc-pertechnetate obtained as the first elution of a new generator and/or 99mTc-pertechnetate more than 12 hr old. Several of the substandard products involved other preparation factors and/or human error. CONCLUSION The majority of substandard 99mTc radiopharmaceutical products involved the use of 99mTc-pertechnetate containing excessive amounts of 99Tc and/or oxidizing impurities to prepare products containing relatively small amounts of stannous. Although substandard products are an infrequent occurrence, radiochemical purity testing should be performed routinely on all 99mTc radiopharmaceuticals before patient administration.
منابع مشابه
Prediction of the structural and spectral properties for L,L-ethylenedicysteine diethylester (EC) and its complex with Technetium-99m radionuclide
The technetium-99m complex of the L,L-ethylenedicysteine diethylester (EC), of the brain imaging agent, was reported as a good choice for replacement of the renal nuclear medicines like OIH radiopharmaceutical. This present research work studies the structural, electronic and spectral properties of the EC compound and its complex with technetium-99m radionuclide from theoretical insight. All co...
متن کاملThe Feasibility of Thyroid Treatment with 99mTc Radiopharmaceuticals and Stable Iodine as Contrast Agent Using MCNP Simulation Code
Introduction: Nowadays, radioisotopes have a lot of therapeutic and diagnostic applications in nuclear medicine. The technetium-99m radioisotope is widely used in the diagnostic field. The technetium-99m radioisotope is widely used in the diagnostic field. In this study, in order to increase the absorption dose in thyroid cancer cells, the radioactive drug technetium-99m which ...
متن کاملPreparation, formulation and quality control of one step kit 99mTc- EDDA/HYNIC-Tyr3-Octreotide as a peptide radiopharmaceutical for imaging somatostatin receptor positive tumors [Persian]
The high expression of somatostatin receptors in many tumours, have made receptor scintigraphy with 111In-DTPA-Octreotide a widly used procedure in nuclear medicine. Despite its clinical success, some limitation and drawbacks of radiolabelling with 111In remain, especially those concerned with the cost, availability and physical decay properties of this radionuclide. 99mTc-EDDA/HYNIC-Tyr3...
متن کاملOn-Site Preparation of Tc-99m Albumin for Clinical Application
WANG, Y.F., CHUANG, M.H., CHIU, J.S., CHAM, T.M. and CHUNG, M.I. On-Site Preparation of Technetium-99m Labeled Human Serum Albumin for Clinical Application. Tohoku J. Exp. Med., 2007, 211 (4), 379-385 ── Technetium-99m labeled human serum albumin (Tc-99m HSA) is an important radiopharmaceutical for clinical applications, such as cardiac function tests or protein-losing gastroenteropathy assessm...
متن کاملAssessment of molybdenum breakthrough levels in molybdenum-99/technetium-99m generators: One year experience at NIMRA Jamshoro Pakistan
Background: Technetium-99m radioisotope is the backbone of any nuclear medicine institute. This radioisotope is acquired by the elution of Molybdenum-99/Technetium-99m generator which emits 141 keV gamma ray and having 6.04 hour half-life. Occasionally the contents of Molybdenum-99 may mix up with elute, which may affect image quality and patients may receive higher doses than recommended. This...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 26 4 شماره
صفحات -
تاریخ انتشار 1998