Behaviour of Corroded Single Stud Shear Connectors

نویسندگان

  • Wen Xue
  • Ju Chen
  • Ji-Hua Zhu
چکیده

In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested. The test specimens were firstly corroded to different corrosion rates by the electronic accelerating method. Static loading tests were then performed to obtain the load-slip curves and ultimate strengths of the corroded test specimens. The actual corrosion rates were measured from the studs obtained from the tested specimens. The test results were compared with the push out test specimens having similar corrosion rates. It is shown that the test results obtained from the single stud shear connectors are conservative compared with the corroded push test specimens, which prove the validation of the single stud shear connector test method. The effect of corrosion on the behavior of stud shear connectors was also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Testing and numerical modelling of Steel-Concrete-Steel with stud bolts connectors subject to push-out loading

Steel-concrete-steel (SCS) sandwich panels are composed of two steel plates with low thicknesses and high densities and strengths and one thick layer between both plates with low strength and density known as core that is composed of concrete. Cohesive material-epoxy resin or shear connectors are usually used to connect the plates to the concrete core. SCS sandwich composites are being develope...

متن کامل

Behaviour of Corroded Stud Shear Connectors under Fatigue Loading

Experimental investigation was conducted on corroded composite push-out specimens to study the behavior of shear studs subjected to fatigue loading. A total of eight standard EC4 push-out specimens were tested. The expected corrosion rate of test specimens ranged from 0 to 50%. The main purpose of these tests was to determine the fatigue life and the reduction effect caused by the corrosion on ...

متن کامل

Local Buckling of Steel Plates in Double Skin Composite Panels under Biaxial Compression and Shear

Steel plates in double skin composite (DSC) panels are restrained by a concrete core and welded stud shear connectors at discrete positions. Local buckling of steel plates in DSC panels may occur in a unilateral mode between stud shear connectors when subjected to combined states of stresses. This paper studies the local and post-local buckling strength of steel plates in DSC panels under biaxi...

متن کامل

Tests to Determine the Joint Stiffness and Resisting Moment Capacity of Joints in Timber-Framed Houses

Wind and earthquake disasters in the world often cause billions of dollars of damage to buildings, most of which is to non-engineered buildings-especially homes. Wood-frame homes use connectors which exhibit partial rotational rigidity at the member ends, making analytical solutions difficult. This is due to the lack of information about the complex behavior of the connections used in this type...

متن کامل

Shear Capacity of C-Shaped and L-Shaped Angle Shear Connectors

This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017