Derivatives of 1-naphthyl ethylenediamine dihydrochloride for standardization of direct-bilirubin assays done with the Technicon "SMAC".
نویسندگان
چکیده
The Jendrassik--Groff assay for direct bilirubin was adapted for analysis rates of 150/h on the Technicon "SMAC" continuous-flow analyzer. This requires development of a standard that is compatible with the other 19 channels on this analyzer. N-1-Naphthyl ethylenediamine dihydrochloride has been used for standardization of direct bilirubin assays, but we found it to be unsuitable because values for potassium are falsely elevated when potassium is determined with a valinomycin ion-selective electrode. This interference can be eliminated by alkylating the aliphatic amine group in the standard. The resulting compounds undergo the coupling reaction in the same way as the original compound and function equally well as standards for the direct bilirubin reaction. The only limitation of these analogs is their decreased solubility at physiological pH in some cases. Thus only certain alkyl groups are suitable.
منابع مشابه
A spectrophotometric method for the direct detection and quantitation of nitric oxide, nitrite, and nitrate in cell culture media.
A method for the spectrophotometric determination of nitric oxide, nitrite, and nitrate in tissue culture media is presented. The method is based on the nitric oxide-mediated nitrosative modification of sulfanilic acid that reacts with N-(1-naphthyl)ethylenediamine dihydrochloride forming an orange-colored product absorbing at 496 nm. Nitric oxide levels were determined in culture media from th...
متن کاملBioassay of N-(1-naphthyl)ethylenediamine dihydrochloride for possible carcinogenicity.
A bioassay for the possible carcinogenicity of N-(1-naphthyl)ethylenediamine dihydrochloride was conducted using Fischer 344 rats and B6C3F1 mice. N-(1-Naphthyl)ethylenediamine dihydrochloride was administered in the feed, at either of two concentrations, to groups of 50 male and 50 female animals of each species. Twenty-five rats of each sex and 50 mice of each sex were placed on test as contr...
متن کاملComparative interference by haemolysis in automated assays for bilirubin at multiple analyte concentrations
The negative interference caused by haemolysis in manual bilirubin assays contrasts with the positive interference reported for some automated methods utilizing the same basic chemistry. A comparison was therefore made of the haemolysis interference associated with several automated bilirubin methodologies: multilayer film (Kodak Ektachem- total bilirubin (TBil), direct bilirubin (DBil), conjug...
متن کاملEvaluation of the co-immobilized hexokinase/glucose-6-phosphate dehydrogenase method for glucose, as adapted to the Technicon SMAC.
We assessed the analytical performance of the co-immobilized hexokinase (EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) method for D-glucose analysis on the Technicon SMAC. The enzyme-containing coils were usable for one month, or 12 000 tests. Bilirubin, hemoglobin, lipemia, creatinine, uric acid, citric acid, and ascorbic acid did not interfere. Results with this method were ...
متن کاملApplication of Poly(N, N′- dibromo-N-ethyl-naphthyl-2,7-disulfonamide) for the Regioselective Synthesis of New 3-Sulfenyl Indole Derivatives
Electron-rich aza-aromatic compounds such as indoles is structures of particular interest and importancein organic chemistry. A useful procedure for the preparation of new 3-sulfenyl indole derivatives using S-alkyl or S-arylthiophthalimides as sulfenylating agents and poly(N, N′-dibromo-N-ethyl-naphthyl-2,7-disulfonamide) as novel catalyst is described. The method represents an efficient prepa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 22 7 شماره
صفحات -
تاریخ انتشار 1976