Partially recanalized chronic dural sinus thrombosis: findings on MR imaging, time-of-flight MR venography, and contrast-enhanced MR venography.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The imaging appearance of chronic, partially recanalized dural sinus thrombosis has been incompletely described. We sought to more fully characterize the imaging findings of this entity on MR imaging, time-of-flight MR venography (TOF-MRV), and elliptic centric-ordered contrast-enhanced MR venography (CE-MRV). MATERIALS AND METHODS From a data base of patients with cerebral venous thrombosis, 10 patients were identified with imaging and clinical findings consistent with the diagnosis of chronic, partially recanalized, dural sinus thrombosis. All patients had MR imaging of the brain without and with contrast. Nine patients underwent MRV, and 6 had both CE-MRV and TOF-MRV. Thirty-four venous segments were thrombosed and were assessed in detail for multiple imaging features. RESULTS Most thrombosed segments were isointense to gray matter on T1-weighted images (85%), and hyperintense to gray matter on T2-weighted images (97%). Visible serpiginous intrathrombus flow voids were visible in 23 segments (8/10 patients) corresponding with areas of flow signal intensity on TOF-MRV and enhancing channels on contrast MRV. Eighty-four percent of thrombosed segments enhanced equal to or greater than venographically normal venous sinuses. TOF-MRV and CE-MRV were abnormal in all patients, and CE-MRV more completely characterized the thrombosed segments. The imaging appearance did not change in those patients with follow-up imaging (average 13.6 months). CONCLUSION Chronic, partially recanalized, venous thrombosis has a characteristic appearance on MR and MRV. CE-MRV was abnormal in all cases, despite the intense enhancement of the thrombosed segments. Because of the highly selected nature of the cases reported, further study is required to determine whether these findings are present in all cases of this condition.
منابع مشابه
Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.
BACKGROUND AND PURPOSE The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous flow on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, ...
متن کاملImaging of cerebral venous thrombosis: current techniques, spectrum of findings, and diagnostic pitfalls.
Cerebral venous thrombosis is a relatively uncommon but serious neurologic disorder that is potentially reversible with prompt diagnosis and appropriate medical care. Because the possible causal factors and clinical manifestations of this disorder are many and varied, imaging plays a primary role in the diagnosis. Magnetic resonance (MR) imaging, un-enhanced computed tomography (CT), unenhanced...
متن کاملCerebral MR venography: normal anatomy and potential diagnostic pitfalls.
BACKGROUND AND PURPOSE MR venography is often used to examine the intracranial venous system, particularly in the evaluation of dural sinus thrombosis. The purpose of this study was to evaluate the use of MR venography in the depiction of the normal intracranial venous anatomy and its variants, to assess its potential pitfalls in the diagnosis of dural venous sinus thrombosis, and to compare th...
متن کاملGadolinium-enhanced MR of chronic dural sinus thrombosis.
Gadopentetate dimeglumine-enhanced MR imaging was performed in four patients with chronic dual sinus thrombosis. After injection, intense enhancement of the chronic thrombus was observed in all cases. On three-dimensional time-of-flight MR angiography, performed in one case, the occluded part of the superior sagittal sinus was not distinguishable from a normal sinus because of thrombus enhancem...
متن کاملCerebral venous thrombosis: diagnostic accuracy of combined, dynamic and static, contrast-enhanced 4D MR venography.
BACKGROUND AND PURPOSE MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.5 seconds per dataset) and static (voxel size, 1.1 x 0.9 x 1.5 mm), contrast-enhanced MRV method (combo-4D MRV) relative to other established MR/MRV modalities. MAT...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 4 شماره
صفحات -
تاریخ انتشار 2007