Model-based quantification of myocardial perfusion images from SPECT.

نویسندگان

  • J Nuyts
  • L Mortelmans
  • P Suetens
  • A Oosterlinck
  • M de Rou
چکیده

A system for quantitative analysis of myocardial perfusion tomograms is proposed. The system starts with an automated delineation of the total left ventricle, including possible perfusion defects, to determine the mass and shape of the myocardium. Next, polar maps or bulls-eyes are computed from the delineation, which can then be compared to reference bulls-eyes to detect perfusion defects. The proposed system differs in three main aspects from currently available bulls-eye algorithms. First, radial slices are used rather than short-axis slices. In this way three-dimensional gradient information is retained, in particular near the base and the apex of the left ventricle. Moreover, the reproducibility of this method is expected to be superior, since the interactive selection of short axis slices through the left ventricle is eliminated. Second, the left ventricle is automatically delineated using a flexible computer model in order to obtain higher reproducibility. The resulting delineation contains both mass and shape information. Third, in addition to the classic count rate bulls-eye, a mass bulls-eye is computed, which contains the myocardial mass corresponding to each bulls-eye pixel. Analysis of the count rate bulls-eye reveals perfusion defects, the quantification of the defects is carried out with the mass bulls-eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 30 12  شماره 

صفحات  -

تاریخ انتشار 1989