Reproducibility of retinal thickness measurements in patients with age-related macular degeneration using 3D Fourier-domain optical coherence tomography (OCT) (Topcon 3D-OCT 1000).

نویسندگان

  • Marcel N Menke
  • Simeon Dabov
  • Pascal Knecht
  • Veit Sturm
چکیده

PURPOSE Conventional time-domain optical coherence tomography (OCT) has become an important tool for following dry or exudative age-related macular degeneration (AMD). Fourier-domain three-dimensional (3D) OCT was recently introduced. This study tested the reproducibility of 3D-OCT retinal thickness measurements in patients with dry and exudative AMD. METHODS Ten eyes with dry AMD and 12 eyes with exudative AMD were included in the study. Sets of three OCT 6 × 6-mm raster scans were taken by one operator. Mean retinal thickness was calculated for 36 areas. Coefficients of variation (CoV) were calculated for each patient and area. For analysis, two separate areas (central and peripheral) were defined. Generalized estimating equations (GEEs) were applied to all 36 subfields in order to analyse possible differences in CoV and mean retinal thickness between dry and exudative AMD. RESULTS Mean retinal thickness values were significantly larger in the central area in exudative AMD (p < 0.001). Mean CoV for exudative AMD was 3.7% (standard deviation [SD] 1.4%). Mean CoV for dry AMD was 1.8 (SD 0.6%). The reproducibility of retinal thickness measurements was significantly less in exudative AMD (p = 0.009). CONCLUSIONS Reproducibility of 3D-OCT retinal thickness measurements was good in both groups. However, reproducibility was significantly better in dry AMD than in exudative AMD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of spectral/Fourier domain optical coherence tomography instruments for assessment of normal macular thickness.

PURPOSE The purpose of this study was to report normal macular thickness measurements and assess reproducibility of retinal thickness measurements acquired by a time-domain optical coherence tomography (OCT) (Stratus, Carl Zeiss Meditec, Inc., Dublin, CA) and three commercially available spectral/Fourier domain OCT instruments (Cirrus HD-OCT, Carl Zeiss Meditec, Inc.; RTVue-100, Optovue, Inc., ...

متن کامل

Assessment of artifacts and reproducibility across spectral- and time-domain optical coherence tomography devices.

PURPOSE To report the frequency of optical coherence tomography (OCT) scan artifacts and to compare macular thickness measurements, interscan reproducibility, and interdevice agreeability across 3 spectral-domain (SD) OCT (also known as Fourier domain; Cirrus HD-OCT, RTVue-100, and Topcon 3D-OCT 1000) devices and 1 time-domain (TD) OCT (Stratus OCT) device. DESIGN Prospective, noncomparative,...

متن کامل

Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography

AIM To evaluate repeatability and reproducibility of macular thickness measurements in visually normal eyes using the Topcon 3D OCT-1000. METHODS Phase 1 investigated scan repeatability, the effect of age and pupil dilation. Two groups (6 younger and 6 older participants) had one eye scanned 5 times pre and post- dilation by 1 operator. Phase 2 investigated between-operator, within and betwee...

متن کامل

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

Comparison of Spectral/Fourier Domain Optical Coherence Tomography Instruments for Assessment of Normal Macular Thickness Citation

PURPOSE—To report normal macular thickness measurements and assess reproducibility of retinal thickness measurements acquired by a time domain optical coherence tomography (OCT) (Stratus [Carl Zeiss Meditec, Inc., Dublin, CA, USA]) and three commercially available spectral / Fourier domain OCT instruments (Cirrus HD-OCT [Carl Zeiss Meditec, Inc., Dublin, CA, USA], RTVue-100 [Optovue, Inc., Frem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta ophthalmologica

دوره 89 4  شماره 

صفحات  -

تاریخ انتشار 2011