Preservation of sputum samples with cetylpyridinium chloride (CPC) for tuberculosis cultures and Xpert MTB/RIF in a low-income country
نویسندگان
چکیده
BACKGROUND Culture contamination with environmental bacteria is a major challenge in tuberculosis (TB) laboratories in hot and humid climate zones. We studied the effect of cetylpyridinium chloride (CPC) preservation on culture results and performance of Xpert MTB/RIF. METHODS Consecutive sputum samples from microscopy smear-positive TB patients were collected. Two-hundred samples were equally split in two aliquots, one aliquot was treated with CPC and stored at ambient temperature for 7 days. The second aliquot was immediately processed. Samples were decontaminated for 20, 15 or 10 min, and subsequently cultured on Löwenstein-Jensen medium. Furthermore, 50 samples were stored for 7, 14 and 21 days, and 100 CPC-pretreated samples tested by Xpert MTB/RIF. RESULTS CPC pretreated samples showed a higher culture yield compared to non-treated sputum samples across all decontamination times: 94% vs. 73% at 10 min (p = 0.01), 94% vs. 64% at 15 min (p = 0.004), and 90% vs. 52% at 20 min (p < 0.001). The quantitative culture grading was consistently higher in CPC treated compared to non-CPC treated samples. The proportion of contaminated cultures was lower in CPC pretreated samples across all decontamination times (range 2-6%) compared to non-CPC treated samples (15-16%). For storage times of CPC treated samples of 7, 14, and 21 days, 84, 86, and 84% of the respective cultures were positive. Of 91 CPC treated samples with a positive culture, 90 were also Xpert MTB/RIF positive. CONCLUSIONS CPC increases culture yield, decreases the proportion of contamination, and does not alter the performance of Xpert MTB/RIF.
منابع مشابه
Xpert MTB/RIF test performance assay in respiratory samples at real work settings in a developing country.
INTRODUCTION The Xpert MTB/RIF test detects DNA from Mycobacterium tuberculosis complex and susceptibility to rifampin. It has been evaluated repeatedly under "ideal" conditions including centrifugation of sputum and bronchoalveolar lavage, Ziehl Neelsen (ZN) and auramine/rhodamine staining, as well as with solid and liquid automated culture methods. Results from such evaluations cannot be extr...
متن کاملEvaluation of Xpert® MTB/RIF Assay in Induced Sputum and Gastric Lavage Samples from Young Children with Suspected Tuberculosis from the MVA85A TB Vaccine Trial
OBJECTIVE Diagnosis of childhood tuberculosis is limited by the paucibacillary respiratory samples obtained from young children with pulmonary disease. We aimed to compare accuracy of the Xpert® MTB/RIF assay, an automated nucleic acid amplification test, between induced sputum and gastric lavage samples from young children in a tuberculosis endemic setting. METHODS We analyzed standardized d...
متن کاملPerformance of Xpert MTB/RIF in induced sputum samples at detecting Mycobacterium tuberculosis.
TO THE EDITOR—In the 1 April 2014 issue of Clinical Infectious Diseases, Sohn et al [1] evaluated the performance of the Xpert MTB/RIF assay at a pulmonary referral center in Montreal, a city with low tuberculosis incidence. The investigators found that the overall sensitivity of the test was 46%, compared with mycobacterial cultures. The article and the accompanying editorial question whether ...
متن کاملIntensified Tuberculosis Case-Finding in HIV-Positive Adults Managed at Ethiopian Health Centers: Diagnostic Yield of Xpert MTB/RIF Compared with Smear Microscopy and Liquid Culture
BACKGROUND Detection of active tuberculosis (TB) before antiretroviral therapy (ART) initiation is important, but optimal diagnostic methods for use in resource-limited settings are lacking. We assessed the prevalence of TB, evaluated the diagnostic yield of Xpert MTB/RIF in comparison with smear microscopy and culture, and the impact of Xpert results on clinical management in HIV-positive adul...
متن کاملRapid diagnosis of tuberculosis using Xpert MTB/RIF assay - Report from a developing country
OBJECTIVE To evaluate the diagnostic accuracy of the Xpert MTB/RIF assay for the detection of M. tuberculosis in pulmonary and extrapulmonary specimens and to compare it with conventional techniques. METHODS During a period of 10 months from December 2012 through September 2013, two hundred and forty five clinically TB suspects were enrolled for Xpert MTB\RIF assay. The cohort comprised of 20...
متن کامل