Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and 137Cs Gamma-Ray Beams

نویسندگان

  • Michelle O’Brien
  • Ronaldo Minniti
  • Stanslaus Alwyn Masinza
چکیده

Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray reference radiation beams of energies between 80 kV and 150 kV and in a cesium 137 gamma-ray beam. The reference radiation qualities used for this comparison are described in detail in the ISO 4037 publication.[1] The comparison began in September 2008 and was completed in March 2009. The results reveal the degree to which the participating calibration facility can demonstrate proficiency in transferring air kerma calibrations under the conditions of the said facility at the time of the measurements. The comparison of the calibration coefficients is based on the average ratios of calibration coefficients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the air kerma standards for 137 Cs and 60 Co gamma - ray beams between the IAEA and the NIST

A comparison of the air kerma standards for Cs and Co gamma ray beams was performed between the NIST and the IAEA. Two reference class ionization chambers owned by the IAEA were used as part of this comparison and were calibrated at each facility. The calibration coefficients, NK, were determined for both chambers and in both gamma-ray beams. The measurements were performed at the IAEA and NIST...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Validation testing of ANSI/IEEE n42.49 standard requirements for personal emergency radiation detectors.

Various radiation detectors including electronic personal emergency radiation detectors (PERDs), radiochromic film cards and thermoluminescent dosimeters (TLDs) were used to validate a subset of the radiological test requirements listed in the American National Standards Institute/The Institute of Electrical and Electronic Engineers (ANSI/IEEE) N42.49 standard. The subset of tests included the ...

متن کامل

Comparison of the NIST and ENEA Air Kerma Standards

A comparison was made between the National Institute of Standards and Technology (NIST) and Ente per le Nuove Tecnologie l'Energia e l'Ambiente (ENEA) air kerma standards for medium energy x rays and 60Co gamma rays. The comparison took place at ENEA in June 1994. Two different transfer chambers from NIST were used for the comparison. The measurements were made at radiation qualities similar to...

متن کامل

The effect of scattered photons for x-ray air-kerma calibrations

The parallel-plate free-air ionization chambers are used for X-rays air-kerma rate standards at National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST). The diaphragms are used to free-air chambers to fix the air volume of ionizing region in chambers. It means that absolute air-kerma rates are defined for collimated x-ray beams, beca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 115  شماره 

صفحات  -

تاریخ انتشار 2010