A Meta-Analysis Of Quadripolar Versus Bipolar Left Ventricular Leads On Post-Procedural Outcomes.
نویسندگان
چکیده
Objective: We aimed to perform a meta-analysis from eligible studies to analyze the true impact of QL when compared with BL with regard to post-procedural outcomes including lead deactivation, revision or replacement. Background: Many observational and retrospective studies showed that quadripolar left ventricular leads (QL) are associated with better outcomes and fewer complications when compared with bipolar leads (BL). Methods: We performed a comprehensive literature search through June 30, 2015 using: quadripolar, bipolar, left ventricular lead and CRT in Pubmed, Ebsco and google scholar databases. Results: The analysis included 8 studies comparing QL and BL implantation. Post-procedural outcomes such as lead deactivation, revision or replacement were used as primary outcome and assessed with Mantel-Haenszel risk ratio (RR). Secondary outcomes included total fluoroscopy/procedure time, occurrence of phrenic nerve stimulation (PNS) and all-cause mortality on follow up. Follow-up duration for the studies ranged from 3 to 60 months. Compared with BL, the use of QL is associated with 52 % reduction (relative risk 0.48; 95% CI: 0.36-0.64, p=0.00001) in the risk of deactivation, revision or replacement of the LV lead. QL had significantly lower fluoroscopy/procedure time, PNS and all-cause mortality when compared with BL. Conclusion:Our meta-analysis shows that QL implantation was associated with decreased risk of LV lead deactivation, revision or replacement when compared with BL.
منابع مشابه
Lead related complications in quadripolar versus bipolar left ventricular leads
BACKGROUND Quadripolar left ventricular (LV) leads are capable of pacing from four different electrodes which allows for easier and more stable intra-operative lead positioning with optimal pacing parameters. We therefore investigated the rate of combined intra-operative and post-operative LV lead related events in quadripolar vs. bipolar LV lead cardiac resynchronization therapy (CRT) recipien...
متن کاملCardiac Resynchronization Therapy Delivered Via a Multipolar Left Ventricular Lead is Associated with Reduced Mortality and Elimination of Phrenic Nerve Stimulation: Long‐Term Follow‐Up from a Multicenter Registry
INTRODUCTION Cardiac resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides more pacing vectors compared to bipolar leads. This may avoid phrenic nerve stimulation (PNS) and allow optimal lead placement to maximize biventricular pacing. However, a long-term improvement in patient outcome has yet to be demonstrated. METHODS A total of 721 consecutive patients wi...
متن کاملAcute and mid-term outcomes of transvenous implant of a new left ventricular quadripolar lead versus bipolar leads for cardiac resynchronization therapy: results from a single-center prospective database.
BACKGROUND The purpose of this study was to evaluate the feasibility of the use of a quadripolar left ventricular (LV) lead for cardiac resynchronization therapy and to compare its acute and mid-term outcomes with those obtained with bipolar leads. Cardiac resynchronization exhibits a high incidence of problems involving the LV lead when conventional leads are used, and these problems may be mi...
متن کاملCost-Effectiveness Analysis of Quadripolar Versus Bipolar Left Ventricular Leads for Cardiac Resynchronization Defibrillator Therapy in a Large, Multicenter UK Registry
OBJECTIVES The objective of this study was to evaluate the cost-effectiveness of quadripolar versus bipolar cardiac resynchronization defibrillator therapy systems. BACKGROUND Quadripolar left ventricular (LV) leads for cardiac resynchronization therapy reduce phrenic nerve stimulation (PNS) and are associated with reduced mortality compared with bipolar leads. METHODS A total of 606 patien...
متن کاملHospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar vs. bipolar left ventricular leads: a comparative effectiveness study
AIMS This study compares, from a prospective, observational, non-randomized registry, the post-implant hospitalization rates and associated healthcare resource utilization of cardiac resynchronization therapy-defibrillator (CRT-D) patients with quadripolar (QUAD) vs. bipolar (BIP) left ventricular (LV) leads. METHODS AND RESULTS Between January 2009 and December 2012, 193 consecutive patients...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of atrial fibrillation
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2016