Laser induced fluorescence photobleaching anemometer for microfluidic devices.

نویسنده

  • G R Wang
چکیده

We have developed a novel, non-intrusive fluid velocity measurement method based on photobleaching of a fluorescent dye for microfluidic devices. The residence time of the fluorescent dye in a laser beam depends on the flow velocity and approximately corresponds to the decaying time of the photobleaching of the dye in the laser beam. The residence time is inversely proportional to the flow velocity. The fluorescence intensity increases with the flow velocity due to the decrease of the residence time. A calibration curve between fluorescence intensity and known flow velocity should be obtained first. The calibration relationship is then used to calculate the flow velocity directly from the measured fluorescence intensity signal. The new method can measure the velocity very quickly and is easy to use. It is demonstrated for both pressure driven flow and electroosmotic flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of photobleaching and velocity fluctuations on single-point LIF measurements

This study investigates the effect of photobleaching on laser-induced fluorescence (LIF) measurements. Photobleaching causes the fluorescence to be velocity-dependent, which is undesirable if quantitative measurements are being made. To quantify this effect, simultaneous and coincident measurements of fluorescence and velocity were made within the measuring volume of a three-beam laser-Doppler ...

متن کامل

Effect of velocity on microdroplet fluorescence quantified by laser-induced fluorescence.

Microdroplets generated inside microfluidic devices have been widely used as miniaturized chemical and biological reactors allowing important reductions in experimental fluid volumes and making it possible to carry out high-throughput assays. Laser-induced fluorescence (LIF) is commonly used to detect and quantify the product, marker or cell content inside each individual droplet. In this work,...

متن کامل

Microfluidic cell sorter for use in developing red fluorescent proteins with improved photostability 3

This paper presents a novel microfluidic cytometer for mammalian cells that rapidly measures the irreversible photobleaching of red fluorescent proteins expressed within each cell and achieves high purity (.99%) selection of individual cells based on these measurements. The selection is achieved by using submillisecond timed control of a piezo-tilt mirror to steer a focused 1064-nm laser spot f...

متن کامل

Flow control valves for analytical microfluidic chips without mechanical parts based on thermally responsive monolithic polymers.

Monolithic plugs of poly(N-isopropylacrylamide) cross-linked with 5% methylenebisacrylamide have been prepared by photoinitiated polymerization within the channel of a microfluidic device. The volume change associated with the polymer phase transition at its lower critical solution temperature of 32 degrees C allows both the rapid swelling and the deswelling of the monoliths enabling the polyme...

متن کامل

The effect of photobleaching on PLIF

Organic dyes commonly used for planar laser-induced fluorescence (PLIF) are susceptible to photobleaching under laser excitation. Previous work has shown that photobleaching can induce significant errors in laser-induced fluorescence measurements made with single-point techniques. This paper presents an analytical model and experimental results that quantify the extent of photobleaching in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 2005