Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems
نویسندگان
چکیده
Accumulated signal noise will cause the integrated values to drift from the true value when measuring orientation angles of wearable sensors. This work proposes a novel method to reduce the effect of this drift to accurately measure human gait using wearable sensors. Firstly, an infinite impulse response (IIR) digital 4th order Butterworth filter was implemented to remove the noise from the raw gyro sensor data. Secondly, the mode value of the static state gyro sensor data was subtracted from the measured data to remove offset values. Thirdly, a robust double derivative and integration method was introduced to remove any remaining drift error from the data. Lastly, sensor attachment errors were minimized by establishing the gravitational acceleration vector from the acceleration data at standing upright and sitting posture. These improvements proposed allowed for removing the drift effect, and showed an average of 2.1°, 33.3°, 15.6° difference for the hip knee and ankle joint flexion/extension angle, when compared to without implementation. Kinematic and spatio-temporal gait parameters were also calculated from the heel-contact and toe-off timing of the foot. The data provided in this work showed potential of using wearable sensors in clinical evaluation of patients with gait-related diseases.
منابع مشابه
Estimation of Temporal Gait Parameters Using a Wearable Microphone-Sensor-Based System
Most existing wearable gait analysis methods focus on the analysis of data obtained from inertial sensors. This paper proposes a novel, low-cost, wireless and wearable gait analysis system which uses microphone sensors to collect footstep sound signals during walking. This is the first time a microphone sensor is used as a wearable gait analysis device as far as we know. Based on this system, a...
متن کاملWearable sensors for gait analysis Comparison between a MIMUs system and a gold standard electromechanical system
Systems based on inertial sensors are increasingly used in motion analysis due to their low cost, portability and wearability. However, since accuracy is crucial in clinical gait analysis, it is important to assess it in new systems. The aim of this study is to compare the performances of a magnetic and inertial sensors system (MIMUs) to a gold standard, the electromechanical system STEP32. Res...
متن کاملKey Design Parameters and Sensor-fusion for Low-power Wearable Uwb-based Motion Tracking and Gait Analysis Systems
Recently, we proposed a wireless ambulatory gait analysis system that provides a high ranging accuracy using ultrawideband (UWB) transceivers. In this paper, we further investigate the performance of our proposed system including ranging using suboptimal templates, power consumption, and sensor-fusion. We show that the proposed system is capable of providing a 1.1 mm ranging accuracy (11.7 mm f...
متن کاملDesign and development of ShrewdShoe, a smart pressure sensitive wearable platform
This study introduces a wearable in-shoe system for real-time monitoring and measurement of the plantar pressure distribution of the foot using eleven sensing elements. The sensing elements utilized in ShrewdShoe have been designed in an innovative way, they are based on a barometric pressure sensor covered with a silicon coating. The presented sensing element has great linearity up to 300...
متن کاملAssessing abnormal gaits of Parkinson’s disease patients using a wearable motion detector
Accelerometers have been widely used in wearable systems for gait analysis. Several gait cycle parameters are provided to quantify the level of gait regularity and symmetry. This study attempts to assess abnormal gaits of Parkinson disease (PD) patients based on the gait cycle parameters derived in real-time from an accelerometry-based wearable motion detector. The results of an experiment with...
متن کامل