Research efforts have been directed towards constructing a fully automated microcomputer-controlled bench-scale 'batch-type' chemical reactor [1-6]. This fully automated reactor can execute repetitive experiments on an approximately 50 ml scale, providing important chemical reaction data during early stages of process development research programmes. The precision and accuracy of the reagent/solvent delivery systems, chemical analysis systems and temperature-control systems are, ofcourse, of fundamental concern. Fail-safe operation is an equally important design consideration if the apparatus is to be used in an unattended operation mode. Particular emphasis has been placed on both self-checking features (for example flow monitors verify proper solution movement through Teflon delivery lines) and fail-safe recovery (engineered into hardware and designed into the automation software). A key hardware element in the fail-safe construction, the opto-isolator interface, has been described previously [1 and 3-6]. With fail-safe operation considerations foremost in mind, a temperature-control system which is controlled by a Digital Equipment Corporation MINC LSI 11/2 computer system and its associated interfaces has been designed and constructed. To effect temperature control in the chemical reactor vessel the opposing actions of systems that remove and add heat to the vessel contents must be balanced. Since the intended application of the apparatus entails repetitive, statistically directed experimentation [7-9], the temperature-control systems must be capable of reaching the designated reaction temperature set-point as quickly as possible (to maximize ramping), thereby minimizing the overall experimentation time. The heating and cooling systems must respond quickly to computer control signals and must have sufficient heating/cooling capacity to effectively respond to and control thermal anomalies ofchemical reactions (for instance endotherms, exotherms).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microfluidics for Chemical Synthesis: Flow Chemistry

Chemical synthesis in microfluidic systems has matured over the two past decades from simple demonstration examples to applications in pharmaceuticals and fine chemicals. Advantages of controlled mixing, enhanced heat and mass transfer, expanded reaction conditions, and safety have driven adoption of continuous flow techniques. The field has moved beyond single transformations to continuous mul...

متن کامل

Automated chemical synthesis. Part 4: Batch-type reactor automation and real-time software design

The ability to efficiently and comprehensively evaluate synthetic routes at their earliest stage of development is especially important in pharmaceutical process research and development and chemical engineering laboratories [1 and 2]. The evaluation and optimization of typically complex synthetic sequences (involving many reaction parameters) frequently entails bench-scale experimentation of a...

متن کامل

Automated chemical synthesis. Part 2: Interfacing strategies

Research focused largely on developing new, highly automated tools for the process development laboratory is carried out in the authors' laboratory. The ability to evaluate, characterize and optimize synthetic routes, both quickly and comprehensively, is especially important in the pharmaceutical process development laboratory, where typically in a complex synthetic sequence many reaction param...

متن کامل

Gallium‐68 DOTATATE Production with Automated PET Radiopharmaceutical Synthesis System: A Three Year Experience

Objective(s): Gallium‐68 (Ga‐68) is an ideal research and hospital‐based PET radioisotope. Currently, the main form of Ga‐68 radiopharmaceutical that is being synthesised in‐house is Ga‐68 conjugated with DOTA based derivatives. The development of automated synthesis systems has increased the reliability, reproducibility and safety of radiopharmaceutical productions. Here we report on our three...

متن کامل

Experimental Investigation on the Synthesis and Size Control of Copper Nanoparticle via Chemical Reduction Method

In this study, synthesis of copper nanoparticles and effect of the reaction conditions on the particle size were investigated. The copper nanoparticles were synthesized and stabilized in a narrow temperature range in the presence of polyvinylpyrrolidone under nitrogen atmosphere. Reaction temperature and concentration ratio of the reducing agent to the precursor (R/P) as two main conditions i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 5  شماره 

صفحات  -

تاریخ انتشار 1983