High Precision UTDR Measurements by Sonic Velocity Compensation with Reference Transducer

نویسندگان

  • Sam Stade
  • Mari Kallioinen
  • Mika Mänttäri
  • Tuure Tuuva
چکیده

An ultrasonic sensor design with sonic velocity compensation is developed to improve the accuracy of distance measurement in membrane modules. High accuracy real-time distance measurements are needed in membrane fouling and compaction studies. The benefits of the sonic velocity compensation with a reference transducer are compared to the sonic velocity calculated with the measured temperature and pressure using the model by Belogol'skii, Sekoyan et al. In the experiments the temperature was changed from 25 to 60 °C at pressures of 0.1, 0.3 and 0.5 MPa. The set measurement distance was 17.8 mm. Distance measurements with sonic velocity compensation were over ten times more accurate than the ones calculated based on the model. Using the reference transducer measured sonic velocity, the standard deviations for the distance measurements varied from 0.6 to 2.0 µm, while using the calculated sonic velocity the standard deviations were 21-39 µm. In industrial liquors, not only the temperature and the pressure, which were studied in this paper, but also the properties of the filtered solution, such as solute concentration, density, viscosity, etc., may vary greatly, leading to inaccuracy in the use of the Belogol'skii, Sekoyan et al. model. Therefore, calibration of the sonic velocity with reference transducers is needed for accurate distance measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Double Transducer for High Precision Ultrasonic Time-Domain Reflectometry Measurements

Membrane fouling, where unwanted particles accumulate on the membrane surface and reduce its permeability, causes problems in membrane filtration processes. With ultrasonic time-domain reflectometry (UTDR) it is possible to measure the extent of membrane fouling and hence take actions to minimize it. However, the usability of UTDR is very limited to constant filtration conditions if the sonic v...

متن کامل

Water Velocity Measurements in Open Channels Using Volumetric Current Meter (VCM)

An innovative Volumetric Current Meter (VCM) was designed in order to allow quick velocity measurements in open channels. At first, the coefficient of velocity (Cv) of the device was determined through calibration under different water velocities in the laboratory. The measurement performance was verified by measurements performed in similar flows in irrigation channels using an ordinary curren...

متن کامل

How Well Can We Measure the Vertical Wind Speed? Implications for Fluxes of Energy and Mass

Sonic anemometers are capable of measuring the wind speed in all three dimensions at high frequencies (10–50 Hz), and are relied upon to estimate eddy-covariance-based fluxes of mass and energy over a wide variety of surfaces and ecosystems. In this study, wind-velocity measurement errors from a three-dimensional sonic anemometer with a nonorthogonal transducer orientation were estimated for ov...

متن کامل

What is the best method for assessing lower limb force-velocity relationship?

This study determined the concurrent validity and reliability of force, velocity and power measurements provided by accelerometry, linear position transducer and Samozino's methods, during loaded squat jumps. 17 subjects performed squat jumps on 2 separate occasions in 7 loading conditions (0-60% of the maximal concentric load). Force, velocity and power patterns were averaged over the push-off...

متن کامل

Accuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements

Background and Purpose:  Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014