Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols

نویسندگان

  • Darren Forst
  • Simrit Nijjar
  • Carlos Flores-Mir
  • Jason Carey
  • Marc Secanell
  • Manuel Lagravere
چکیده

BACKGROUND The objective of this study is to analyze a set of previously developed and proposed image segmentation protocols for precision in both intra- and inter-rater reliability for in vivo tooth volume measurements using cone-beam computed tomography (CBCT) images. METHODS Six 3D volume segmentation procedures were proposed and tested for intra- and inter-rater reliability to quantify maxillary first molar volumes. Ten randomly selected maxillary first molars were measured in vivo in random order three times with 10 days separation between measurements. Intra- and inter-rater agreement for all segmentation procedures was attained using intra-class correlation coefficient (ICC). RESULTS The highest precision was for automated thresholding with manual refinements. CONCLUSIONS A tooth volume measurement protocol for CBCT images employing automated segmentation with manual human refinement on a 2D slice-by-slice basis in all three planes of space possessed excellent intra- and inter-rater reliability. Three-dimensional volume measurements of the entire tooth structure are more precise than 3D volume measurements of only the dental roots apical to the cemento-enamel junction (CEJ).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

بررسی موقعیت آناتومیک و شکل هندسی سوراخ چانه ای در تصاویر Cone Beam Computed Tomography

Introduction & Objective: The mental foramen is a part of lower jaw which has neurovascular bundles and also is important in biology. 3D imaging of this area by cone beam computed tomography (CBCT) before surgery can prevent some problems. This study aims to evaluate the anatomic position and geometrical shape of the mental foramen by CBCT images. Materials & Methods: In this research, the C...

متن کامل

Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines

Introduction: Maxillary canines have important roles in facial appearance, development of arch, and functional occlusion. Radiographs are important in evaluating the location and nature of these anomalies. The purpose of this study was to evaluate two types of 2D and 3D imaging technique in diagnosis and treatment of maxillary impacted canines. Methods: Thirty eight patients (50 impacted canine...

متن کامل

Correction to: An Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography

Correction to: An Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography   Abbas Mesgarani1, Azadeh Zakariaie2, Azam Haddadi Kohsar1, Sina Haghanifar3, Jamshid Yazdani Charati4, Arman Ebrahimi5   1 Assistant Professor, Department of Endodontics, Faculty of Dentistry, Mazandaran University of Medical S...

متن کامل

Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography

Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014