Innervation of tissue-engineered corneal implants in a porcine model: a 1-year in vivo confocal microscopy study.
نویسندگان
چکیده
PURPOSE To examine the pattern of nerve regeneration within tissue-engineered corneal substitutes grafted into host porcine corneas over a 1-year postoperative period. METHODS Biodegradable corneal substitutes from cross-linked collagen were implanted into the left eyes of 12 pigs by deep lamellar keratoplasty. Regeneration of severed nerves into the central implant region was investigated with in vivo confocal microscopy. Both implant-recipient and control (right) eyes were examined before surgery and 2, 6, 10, and 12 months after surgery, to quantify the number, density, diameter, and branching of nerve fiber bundles at various corneal depths. Transmission electron microscopy was used to confirm the presence of nerve bundles. RESULTS Two months after surgery, corneal nerve ingrowth was observed within the deep anterior stroma, with a number and density of regenerated nerves significantly higher than in nonsurgical control eyes (P < 0.01). Nerves within the superficial anterior stroma regenerated by 6 to 10 months after surgery, and the first subbasal epithelial nerves were seen 10 months after surgery. After 1 year, subbasal nerve density recovered to preoperative levels. Nerve fibers in the deep anterior stroma remained significantly thinner relative to control eyes after 1 year (P < 0.001), where both superficial anterior and subbasal nerve diameter did not change relative to control eyes. CONCLUSIONS The pattern of reinnervation within tissue-engineered corneal substitutes has been quantified in vivo. Innervation proceeded rapidly in the deep anterior stroma, followed by repopulation of more superficial regions. One year after surgery, nerve density within the tissue-engineered cornea increased or remained unchanged relative to controls in all corneal regions examined.
منابع مشابه
Innervation of tissue-engineered recombinant human collagen-based corneal substitutes: a comparative in vivo confocal microscopy study.
PURPOSE To compare reinnervation in recombinant human collagen-based corneal substitutes with allografts during a 1-year postimplantation follow-up period in pigs. A retrospective comparison to innervation in porcine collagen-based biosynthetic grafts was also performed. METHODS Pigs received a corneal allograft or a substitute made of either recombinant human type-I or -III collagen. In vivo...
متن کاملVariations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy
Background To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...
متن کاملCorneal sensation after myopic and hyperopic LASIK: clinical and confocal microscopic study.
AIM To assess the long term (1 year) effect of myopic and hyperopic LASIK on corneal sensation and innervation. METHODS 83 eyes of 43 patients having LASIK were evaluated. According to the preoperative spherical equivalent, the eyes were divided into three groups: group 1, myopia from -0.75 to -6.00 D; group 2, myopia from -6.25 to -11.50 D; and group 3, hyperopia from 1.25 to 5.00 D. Corneal...
متن کاملCorneal innervation and cellular changes after corneal transplantation: an in vivo confocal microscopy study.
PURPOSE Although penetrating keratoplasty is generally considered a successful procedure, transplanted corneal tissue may exhibit abnormal epithelium, decreased sensation, and declining endothelial cell counts after surgery. This study aimed to use in vivo confocal microscopy to correlate corneal microstructure and recovery of the subbasal nerve plexus of the transplanted cornea with indication...
متن کاملTissue-engineered recombinant human collagen-based corneal substitutes for implantation: performance of type I versus type III collagen.
PURPOSE To compare the efficacies of recombinant human collagens types I and III as corneal substitutes for implantation. METHODS Recombinant human collagen (13.7%) type I or III was thoroughly mixed with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and N-hydroxysuccinimide. The final homogenous solution was either molded into sheets for in vitro studies or into implants with the appropriate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 48 8 شماره
صفحات -
تاریخ انتشار 2007