Diagnostic use of neuro-spect quantified with 99mTc-ECD a model based on normal data

نویسندگان

  • Belmonte Juarez Marroni
  • Sabine Possa Marroni
  • Caroline Muller Mayer
  • Betina R. Braga
چکیده

OBJECTIVE The purpose of the present study was to prospectively quantify the normal limits of brain perfusion using specific software in a group of asymptomatic young volunteers submitted to single-photon emission tomography (SPECT) with 99mTc-ethyl cysteinate dimer (99mTc-ECD). METHODS We used 15 MBq/kg of intravenous 99mTc-ECD in 30 healthy volunteers submitted to brief neuropsychological tests and a clinical questionnaire. These data were normalized relative to the cerebellum (Group 1) and to the brain cortex (Group 2). Statistical analysis was performed with Student's t-test. The average radioactivity was 6.5 million counts/study. RESULTS The normalized (Group I) revealed an average value of 78.03%, with standard deviation (SD) of 4.07. Two volunteers in this group had slightly greater than two standard deviations from the mean. When we used (Group II), the average value was 71.01%, with a SD of 4.66. We observed a difference between groups of 9% (P<0.001). CONCLUSION The present study suggests normal cortical perfusional values for a group of young asymptomatic volunteers, utilizing 99mTc-ECD. This allows further quantification of neuro-SPECT data, specifically comparisons across patient populations. Furthermore, this method represents a new tool that can be used to further explore the field of neuroimaging, particularly neuropsychiatry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of "super rapid dynamic SPECT," and analysis of retention process of 99mTc-ECD in ischemic lesions: comparative study with 133Xe SPECT.

To analyze the retention process of technetium-99m ethyl cysteinate dimer (99mTc-ECD) in normal and ischemic lesions, we developed a super rapid dynamic SPECT system based on the CERASPECT (DSI, Inc., Waltham, MA, USA). The system made it possible to take a SPECT series every 2 seconds. Each SPECT series contains a maximum of 16 slices (6.6 mm slice interval) in a matrix size of 32 x 32. The se...

متن کامل

A pictorial essay on brain perfusion SPECT in various neuro-psychiatric disorders and intoxication: Though practical, it is not very commonly used

Brain single-photon emission computerized tomography (SPECT), in particular, with perfusion agents or with neuroreceptor imaging radiopharmaceuticals, is rapidly becoming a clinical tool in many neurologic and psychiatric conditions. This imaging modality has been used for diagnosis, prognosis assessment, evaluation of response to therapy, risk stratification, detection of benign vs. malignant ...

متن کامل

Brain perfusion SPECT study with 99mTc-bicisate: clinical pitfalls and improved diagnostic accuracy with a combination of linearization and scatter-attenuation correction.

To evaluate the usefulness of a combination of linearization and scatter-attenuation correction on 99mTc-bicisate (ECD)-single photon emission tomographic (SPECT) images, both cerebral blood flow (CBF)-positron emission tomographic (PET) images and ECD-SPECT images from fifteen patients with chronic cerebral infarction were acquired. We measured radioactivity counts in regions of interest (ROIs...

متن کامل

Comparative study of 99mTc-ECD and 99mTc-HMPAO for peri-ictal SPECT: qualitative and quantitative analysis.

OBJECTIVES Most studies that clinically validated peri-ictal SPECT in intractable partial epilepsy had used technetium-99m-hexamethylpropylene amine oxime (99mTc-HMPAO or 99mTc-exametazime) as the radiopharmaceutical. Because of some theoretical advantages, technetium-99m-ethyl cysteinate diethylester (99mTc-ECD or 99mTc-bicisate) is increasingly being used instead. This study compares unstabil...

متن کامل

Brain single-photon emission CT studies using 99mTc-HMPAO and 99mTc-ECD early after recanalization by local intraarterial thrombolysis in patients with acute embolic middle cerebral artery occlusion.

BACKGROUND AND PURPOSE The brain distribution of 9mTc-hexamethylpropyleneamine oxime (HMPAO) correlates with regional brain perfusion, whereas 99mTc-ethyl cysteinate dimer (ECD) reflects not only perfusion but also the metabolic status of brain tissue. We compared 99mTc-ECD single-photon emission CT (SPECT) with 99mTc-HMPAO SPECT early after recanalization by local intraarterial thrombolysis (L...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013