Endotracheal tube and laryngeal mask airway cuff pressures can exceed critical values during ascent to higher altitude.
نویسندگان
چکیده
OBJECTIVES Tracheal mucosal perfusion is compromised at an endotracheal tube (ETT) cuff pressure of 30 cm H(2)O, and blood flow is obstructed at a pressure of 50 cm H(2)O. METHODS We measured the change in pressure of air-filled cuffs of 6.0 and 7.5 ETTs and a size 4 laryngeal mask airway (LMA) from sea level to 2400 m. The ETTs and LMA cuff measurements were done with the devices uncontained, and an additional 6.0 ETT was placed in a 10-mL syringe barrel to mimic placement in a trachea. This restricted cuff expansion simulating what would occur when it is placed within the trachea. The pressure of fluid-filled 6.0 ETT cuffs was also measured. RESULTS Intracuff pressure increases linearly with increasing altitude, in all air-filled ETT and LMAs. Water-filled cuffs demonstrated no significant change in pressure with changes in altitude. The rate of ETT cuff pressure increase was greater for the ETT restricted within the syringe barrel compared with the unrestricted ETT cuff. The rate of LMA cuff pressure increase was greater than the rate of increase for all the ETTs (restricted and unrestricted). CONCLUSIONS This model indicates that ETT cuffs inflated before air transport are likely to exceed critical pressure levels rapidly during flight. In addition, there will be loss of ETT cuff pressure, with loss of a good seal, during descent if a cuff is initially inflated at peak altitudes. Therefore, we suggest ETT cuff pressures should be monitored and adjusted continuously during ascent and decent.
منابع مشابه
Comparison of mucosal pressures induced by cuffs of different airway devices.
BACKGROUND High pressures exerted by balloons and cuffs of conventional endotracheal tubes, the Combitube (Tyco Healthcare Nellcor Mallinckrodt, Pleasanton, CA), the EasyTube (Teleflex Ruesch, Kernen, Germany), the Laryngeal Mask Airway (LMA North America, San Diego, CA), the Intubating Laryngeal Mask Airway (Fastrach; LMA North America), the ProSeal (LMA North America), and the Laryngeal Tube ...
متن کاملThe Professional Experience of Anaesthesiologists in Proper Inflation of Laryngeal Mask and Endotracheal Tube Cuff.
OBJECTIVE Cuffs inflated to inappropriately high pressures cause ischemia, reducing tracheal mucosal blood flow, while cuffs inflated at lower pressure than necessary give rise to inadequate ventilation, aspiration of gastric contents, or extubation due to air leakage. In this study, we aimed to investigate the effect of the experience of anaesthesia staff on endotracheal tube and laryngeal mas...
متن کاملمقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان
Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...
متن کاملLimitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملSafe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review
Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pediatric emergency care
دوره 27 5 شماره
صفحات -
تاریخ انتشار 2011