Use of aqueous silver to enhance inactivation of coliphage MS-2 by UV disinfection.
نویسندگان
چکیده
A synergistic effect between silver and UV radiation has been observed that can appreciably enhance the effectiveness of UV radiation for inactivation of viruses. At a fluence of ca. 40 mJ/cm(2), the synergistic effect between silver and UV was observed at silver concentrations as low as 10 microg/liter (P < 0.0615). At the same fluence, an MS-2 inactivation of ca. 3.5 logs (99.97%) was achieved at a silver concentration of 0.1 mg/liter, a significant improvement (P < 0.0001) over the ca. 1.8-log (98.42%) inactivation of MS-2 at ca. 40 mJ/cm(2) in the absence of silver. Modified Chick-Watson kinetics were used to model the synergistic effect of silver and UV radiation. For an MS-2 inactivation of 4 logs (99.99%), the coefficient of dilution (n) was determined to be 0.31, which suggests that changes in fluence have a greater influence on inactivation than does a proportionate change in silver concentration.
منابع مشابه
Inactivation of feline calicivirus and adenovirus type 40 by UV radiation.
Little information regarding the effectiveness of UV radiation on the inactivation of caliciviruses and enteric adenoviruses is available. Analysis of human calicivirus resistance to disinfectants is hampered by the lack of animal or cell culture methods that can determine the viruses' infectivity. The inactivation kinetics of enteric adenovirus type 40 (AD40), coliphage MS-2, and feline calici...
متن کاملComparative Inactivation of Bacillus Subtilis Spores and MS-2 Coliphage in a UV Reactor: Implications for Validation
Biodosimetry is the currently accepted method for validation of fluence delivery in ultraviolet UV reactors for water disinfection. This method utilizes the inactivation of a surrogate microorganism to predict the reduction equivalent fluence and subsequent inactivation of a target pathogen. Two common surrogates—Bacillus subtilis spores and MS-2 coliphage—were used to examine the relationship ...
متن کاملUV disinfection of indigenous aerobic spores: implications for UV reactor validation in unfiltered waters.
Conventional validation testing of UV reactors use cultured microorganisms spiked into test water flowing through a reactor. These tests are limited by the microbe titer it is possible to grow, thus limiting the size of the reactor it is possible to validate. The goal of this study was to examine the UV inactivation of indigenous aerobic spores naturally occurring in raw/unfiltered water suppli...
متن کاملCFD Simulation of UV Disinfection Reactor for Applesauce with a Low UV Absorption Coefficient
In this study, a Computational Fluid Dynamics (CFD) model was developed to evaluate ultraviolet disinfection applesauce reactor. To simulate UV reactors, three sets of equations, including hydrodynamics, radiation and species mass conservation were solved simultaneously. The Realizable k-e turbulence model and the discrete ordinate method were used to find the UV radiation profile through the r...
متن کاملAction spectra for validation of pathogen disinfection in medium-pressure ultraviolet (UV) systems.
Ultraviolet (UV) reactors used for disinfecting water and wastewater must be validated and monitored over time. The validation process requires understanding the photochemical properties of the pathogens of concern and the challenge microorganisms used to represent them. Specifically for polychromatic UV systems, the organisms' dose responses to UV light and their sensitivity across the UV spec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 70 5 شماره
صفحات -
تاریخ انتشار 2004