Qualitative evaluation of the reagin screen test.

نویسندگان

  • D A Black
  • P E Ray
  • B L Therrell
چکیده

After a preliminary study of 557 sera used as a procedural training exercise, the Reagin screen test (RST) for the macroscopic detection of reagin (as an aid to detecting syphilis) was qualitatively compared to the rapid plasma Reagin (RPR) (circle) card test and Veneral Disease Research Laboratory (VDRL) slide test on 435 random portions of sera using fluorescent treponemal antibody adsorption (FTA-ABS) results as a comparative base. A comparison of total agreement (positive and negative) with the FTA-ABS results led to the following order. RPRCT (I5.5%), VDRL (79.8%), and RST (74.5%). Of the total samples shown to be reactive by the FTA-ABS procedure, the percentage of these interpreted as nonreactive (i.e., "false negative") by the procedures compared was considerably higher with the RST procedure (29.3%) than with either the RPRCT (10.9%) or the VDRL (7.1%) procedures. Minor problems encountered with procedural techniques are also mentioned.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of NCS rapid plasma reagin card test, a new screening kit for syphilis.

Agreements in qualitative and quantitative test results between the recently marketed NCS rapid plasma reagin card test (NCS Diagnostics Corp.) and the Macro-Vue rapid plasma reagin 18-mm circle card test (Hynson, Westcott and Dunning) were 99.2 and 99.1%, respectively, indicating the NCS RPR card test to be an acceptable alternative procedure for the serodiagnosis of syphilis.

متن کامل

Evaluation of reagin screen, a new serological test for syphilis.

A total of 1,020 serum and plasma specimens were tested using the Venereal Disease Research Laboratory (VDRL), Rapid Plasma Reagin (RPR) card, Reagin Screen (RST) and Fluorescent Treponemal Antibody-Absorption (FTA-ABS) tests. In 257 normal patients, all screening tests were nonreactive; the FTA-ABS test was reactive for one patient. In 588 patients with treated and untreated syphilis, the RST ...

متن کامل

Evaluation of a digital flocculation reader for the rapid plasma reagin test for the serological diagnosis of syphilis.

We described the ASiManager-AT digital flocculation reader to demonstrate concordance between visual and digital readings of the rapid plasma reagin test for detection of antibodies in the serum of patients with syphilis. A qualitative and quantitative rapid plasma reagin was performed on each serum samples giving a concordance of 98.6% and 99.7%, respectively, for reactives and 100% for nonrea...

متن کامل

Comparison between the automated reagin test and reagin screen test methods of VDRL screening tests for syphilis in use in a routine laboratory.

A comparison is made between the automated reagin test (ART) using Technicon AutoAnalyzer equipment and the reagin screen test (RST) introduced by Lederle using a new antigen formulation. Treponemal haemagglutination tests (TPHA) were done simultaneously as second screen tests. The absorbed fluorescent treponemal antibody test (FTA-ABS) was used in all seropositive cases. Altogether 1154 sera w...

متن کامل

Comparison of serum and plasma specimens for syphilis serology using the reagin screen test.

One serum and three plasma samples were obtained from each of 125 normal individuals and from 140 patients with treated or untreated syphilis. Serum samples were tested by the Venereal Disease Research Laboratory (VDRL) test and by the Reagin Screen Test (RST). Plasma specimens were tested only with the RST. When tested within 24 h after collection, all specimens from normal individuals were no...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 4 1  شماره 

صفحات  -

تاریخ انتشار 1976