Combination Effect of Hemostatic and Disinfecting Agents on Micro-leakage of Restorations Bonded with Different Bonding Systems
نویسندگان
چکیده
STATEMENT OF PROBLEM Hemostatic agents may affect the micro-leakage of different adhesive systems. Also, chlorhexidine has shown positive effects on micro-leakage. However, their interaction effect has not been reported yet. OBJECTIVES To evaluate the effect of contamination with a hemostatic agent on micro-leakage of total- and self-etching adhesive systems and the effect of chlorhexidine application after the removal of the hemostatic agent. MATERIALS AND METHODS Standardized Class V cavity was prepared on each of the sixty caries free premolars at the cemento-enamel junction, with the occlusal margin located in enamel and the gingival margin in dentin. Then, the specimens were randomly divided into 6 groups (n = 10) according to hemostatic agent (H) contamination, chlorhexidine (CHX) application, and the type of adhesive systems (Adper Single Bond and Clearfil SE Bond) used. After filling the cavities with resin composite, the root apices were sealed with utility wax. Furthermore, all the surfaces, except for the restorations and 1mm from the margins, were covered with two layers of nail varnish. The teeth were immersed in a 0.5% basic fuschin dye for 24 hours, rinsed, blot-dried and sectioned longitudinally through the center of the restorations bucco- lingualy. The sections were examined using a stereomicroscope and the extension of dye penetration was analyzed according to a non-parametric scale from 0 to 3. Statistical analysis was performed using Kruskal-Wallis test and Mann-Whitney U-test. RESULTS While ASB group showed no micro-leakage in enamel, none of the groups showed complete elimination of micro-leakage from the dentin. Regarding micro-leakage at enamel, and dentin margins, there was no significant difference between groups 1 and 2, 1 and 3, and 2 and 3 (p > 0.05). A significantly lower micro-leakage at the enamel and dentin margins was observed in group 3, compared to group 6. No significant difference was observed between groups 4 and 5 in enamel (p = 0.35) and dentin (p = 0.34). Group 6 showed significantly higher micro-leakage, compared to group 4 and 5 (p < 0.05). CONCLUSIONS Hemostatic agent contamination had no significant effect on micro-leakage of total- and self-etching adhesive systems. Application of chlorhexidine after the removal of hemostatic agent increased micro-leakage in self-etching adhesives but did not affect when total-etching was used.
منابع مشابه
Microleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations
Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This in-vitro study compared the microleakage of three resin-based adhesives versus a GIC-based adhesive on class V composite restorations. Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned ...
متن کاملEffects of Three Hemostatic Agents on Microleakage of Cervical Composite Resin Restorations Bonded to Simulated Caries-Affected Tooth Substrate Using One-Step Self-Etch Adhesive
Background and Aim: This study aimed to evaluate the microleakage of cervical res-torations with the use of a one-step self-etch adhesive after application of three differ-ent hemostatic agents. Materials and Methods: In this in vitro study, 96 cervical cavities were prepared on 24 intact and 24 demineralized teeth. Forty-eight class V cavities with sound tooth substrate were assigned to group...
متن کاملInvestigation of Micro-leakage of Self-cured and Light-cured composite restorations using a universal bonding system
Introduction:One-bottle light-cured adhesives systems have variable pH. In addition to ease of use, universal adhesives can be used in various restorations and different substrates. Due to the lack of studies, the purpose of this study was to compare the enamel and dentin micro-leakage of self-cure and light cure composite restorations using a universal bonding system. Materials & Methods:The ...
متن کاملResearch Paper: Investigation of Micro-leakage of Self-cured and Light-cured composite restorations using a universal bonding system
Abstract Introduction: One-bottle light-cured adhesives systems have variable pH. In addition to ease of use, universal adhesives can be used in various restorations and different substrates. Due to the lack of studies, the purpose of this study was to compare the enamel and dentin micro-leakage of self-cure and light cure composite restorations using a universal bonding system. Materials...
متن کاملAn in vitro study of wet-bonding fissure sealant micro-leakage (Embrace)
An in vitro study of wet-bonding fissure sealant micro-leakage (Embrace) Dr. T. Masoum *- Dr. SH. Kasraie ** - Dr. M. Nafarie *** *Assistant Professor of Pedodontics Dept., Faculty of Dentistry, Hamedan University of Medical Sciences. **Assistant Professor of Operative Dentistry Dept., Faculty of Dentistry, Hamedan University of Medical Sciences. *** Dentist. Abstract Background and Aim: It has...
متن کامل