Superconducting RF Coils for Clinical MR Imaging at Low Field1

نویسندگان

  • Q. Y. Ma
  • K. C. Chan
  • Daniel F. Kacher
  • Erzhen Gao
  • Mei Sim Chow
  • Kelvin K. Wong
  • Hui Xu
  • Edward S. Yang
  • Geoff S. Young
  • Jason R. Miller
  • Ferenc A. Jolesz
چکیده

Rationale and Objectives. A number of recent reports in the MRI literature have established that substantial signal-tonoise ratio (SNR) gains can be achieved with small samples or low resonance frequencies, through the use of high-quality factor high-temperature superconducting (HTS) RF receive coils. We show the application of HTS coils to the imaging of human subjects with improved SNR compared with copper coils. Materials and Methods. HTS coils were constructed from 7.62-cm YBa2Cur3O7thin films on LaAlO3 substrate and cooled in a liquid nitrogen cryostat. Human and phantom images were acquired on a 0.2-T scanner. The SNR improvements compared with equivalent-sized copper coils are reported. Results. SNR gains of 2.8-fold and 1.4-fold were observed in images of a phantom acquired with an HTS coil versus a room temperature copper coil and a liquid nitrogen–cooled copper coil, respectively. Preliminary results suggest higher image quality can be obtained in vivo with an HTS coil compared with copper coil imaging. Images of human orbit, brain, temporomandibular joint, and wrist are presented. Conclusion. The experimental results show that benefits can be expected from application of HTS surface coils in human MR imaging with low-field scanners. These potential benefits justify the continued development of practical HTS coil imaging systems despite the considerable technical difficulties involved in cryostat and coil design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

In Vivo SNR Gains for MR Micro Imaging with Cryo-cooled Copper Coils

Introduction It has recently been demonstrated that substantial SNR enhancements (3.7 times) can be achieved for in vivo MR micro imaging of small animals at 2 T field strength with superconducting RF coils, cooled to 30 K [1]. However, significant SNR gains are expected even with conventional copper coils, cooled with liquid nitrogen (77 K). The latter have several advantages in terms of simpl...

متن کامل

High Temperature Superconducting Radio Frequency Coils for Nmr Spectroscopy and Magnetic Resonance Imaging

High-temperature superconductivity has a significant opportunity to improve the performance of nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) systems. The low rf losses and compact size of superconducting coils allow them to improve the signal-to-noise ratio in applications where the system noise dominates that of the sample under study. These improvements tr...

متن کامل

New horizons in MR technology: RF coil designs and trends.

Parallel imaging techniques have developed very rapidly, and realization of their full potential has required the design of magnetic resonance (MR) scanners with ever-increasing numbers of receiver channels (32 to 128). In particular, 1.5- and 3-Tesla fast MR imaging applications are now used in everyday clinical practice. Both strengths require maximum achievable signal-to-noise ratio (SNR) an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003