Clampless anastomosis: novel device for clampless proximal vein anastomosis in OPCAB surgery--the initial Spyder experience.

نویسندگان

  • Baron L Hamman
  • Cory H White
  • Michael Fontes
  • Lise Labiche
چکیده

The Spyder is a novel device that enables the attachment of a vein to the aorta by compliant, interrupted anastomosis; this minimizes aortic manipulation during off pump-coronary artery bypass (OPCAB) surgery. Its use may reduce transcranial Doppler signals recorded during CABG. We performed 250 anastomoses in 160 OPCAB cases in many centers and recorded efficiency and efficacy data. There were no adverse events noted during the operative period. In a subset of patients in one center, flow (n = 48) and transcranial Doppler signals (n = 22) were measured. We found the device to be a useful adjunct for minimally invasive CABG surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel device for clampless proximal anastomosis in OPCAB surgery: the IPAD.

The Coalescent IPAD (Coalescent Surgical, Sunnyvale, CA, USA) is a novel device that enables creation of a compliant proximal vein anastomosis to the aorta during off-pump coronary artery bypass (OPCAB) surgery while reducing the risk of cerebrovascular emboli and early stenosis. We performed IPAD-created anastomoses in 76 patients having standard OPCAB surgery. Following the procedures, no pat...

متن کامل

Five-year clinical outcome and patency rate of device-dependent venous grafts after clampless OPCAB with PAS-port automated proximal anastomosis: the PAPA Study.

OBJECTIVE To evaluate long-term clinical performance and angiographic patency of automated proximal venous anastomoses following clampless coronary artery bypass (C-CAB). METHODS Observational study in patients submitted for isolated C-CAB and at least one proximal aortosaphenous anastomosis performed with an automated connector (Cardica PAS-Port) including 152 consecutive patients (165 devic...

متن کامل

Clampless off-pump coronary artery bypass prevents early post-operative neurologic injury compared to on-pump: a propensity score matched analysis

Background Unaortic coronary artery bypass with all arterial grafts proved to prevent early neurologic injury. Various devices for clampless proximal anastomosis of venous grafts were associated with an increased risk of microembolism. The Cardica PAS-Port is a new, fully automated device that might be able to obtain safe proximal aorto-venous connection without an increased risk of microor mac...

متن کامل

Minimizing the risk of perioperative stroke by clampless off-pump bypass surgery: a retrospective observational analysis

OBJECTIVES Stroke is a devastating complication after coronary artery bypass grafting, occurring in 1.4% to 4.3% of patients. A major cause of stroke is cerebral embolization of aortic atheromatous debris or calcified plaques. This report analyzes the incidence of stroke in patients treated according to the clampless concept, i.e. avoiding side-clamping of the aorta, by means of off-pump corona...

متن کامل

HEARTSTRING enabled no-touch proximal anastomosis for off-pump coronary artery bypass grafting: current evidence and technique.

Surgical revascularization remains the standard of care for many patients. Off-pump coronary artery bypass grafting (OPCAB) without cardiopulmonary bypass (CPB) has evolved during the past 20 years, and as such can significantly reduce the occurrence of neurological complications. While avoiding the aortic cross-clamping required in conventional on-pump techniques, OPCAB results in a lower inci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 8 6  شماره 

صفحات  -

تاریخ انتشار 2005