Improving arrival time identification in transient elastography.

نویسندگان

  • Jens Klein
  • Joyce McLaughlin
  • Daniel Renzi
چکیده

In this paper, we improve the first step in the arrival time algorithm used for shear wave speed recovery in transient elastography. In transient elastography, a shear wave is initiated at the boundary and the interior displacement of the propagating shear wave is imaged with an ultrasound ultra-fast imaging system. The first step in the arrival time algorithm finds the arrival times of the shear wave by cross correlating displacement time traces (the time history of the displacement at a single point) with a reference time trace located near the shear wave source. The second step finds the shear wave speed from the arrival times. In performing the first step, we observe that the wave pulse decorrelates as it travels through the medium, which leads to inaccurate estimates of the arrival times and ultimately to blurring and artifacts in the shear wave speed image. In particular, wave 'spreading' accounts for much of this decorrelation. Here we remove most of the decorrelation by allowing the reference wave pulse to spread during the cross correlation. This dramatically improves the images obtained from arrival time identification. We illustrate the improvement of this method on phantom and in vivo data obtained from the laboratory of Mathias Fink at ESPCI, Paris.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interior Elastodynamics Inverse Problems: Shear Wave Speed Reconstruction in Transient Elastography

We review and present new results on the transient elastography problem, where the goal is to reconstruct shear stiffness properties using interior time and space dependent displacement measurements. We present unique identifiability of two parameters for this inverse problem, establish that a Lipschitz continuous arrival time satisfies the eikonal equation, and present two numerical algorithms...

متن کامل

Shear wave speed recovery in transient elastography and supersonic imaging using propagating fronts

Transient elastography and supersonic imaging are promising new techniques for characterizing the elasticity of soft tissues. Using this method, an ‘ultrafast imaging’ system (up to 10 000 frames s−1) follows in real time the propagation of a low frequency shear wave. The displacement of the propagating shear wave is measured as a function of time and space. The objective of this paper is to de...

متن کامل

Using level set based inversion of arrival times to recover shear wave speed in transient elastography and supersonic imaging

Transient elastography and supersonic imaging are promising new techniques for characterizing the elasticity of soft tissues. Using this method, an ‘ultrafast imaging’ system (up to 10 000 frames s−1) follows in real time the propagation of a low-frequency shear wave. The displacement of the propagating shear wave is measured as a function of time and space. Here we develop a fast level set bas...

متن کامل

Assessment of transient elastography (FibroScan) for diagnosis of fibrosis in non-alcoholic fatty liver disease: A systematic review and meta-analysis

Background: Transient elastography (TE) is a new modality for the diagnosis of liver fibrosis caused by various etiologies. This study was conducted to determine the accuracy of TE in detecting the different stages of liver fibrosis in non-alcoholic fatty liver disease (NAFLD) patients. Methods: MEDLINE/PubMed, Embase, Ovid, Cochrane Library, American College of Physicians (ACP) Journal Club...

متن کامل

Assessment of hepatic fibrosis by transient elastography in rheumatoid arthritis patients receiving methotrexate

Background and Aim: Methotrexate (MTX) is commonly used in the treatment of diseases such as rheumatoid arthritis (RA) but, its hepatotoxicity potential, always has been a major concern. The aim of this study is to determine the rate of liver fibrosis by transient elastography (TE) method and its relationship with cumulative dose of MTX and duration of treatment, in rheumatoid arthritis patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 57 8  شماره 

صفحات  -

تاریخ انتشار 2012