Simultaneous Detection of Fenitrothion and Chlorpyrifos-Methyl with a Photonic Suspension Array
نویسندگان
چکیده
A technique was developed for simultaneous detection of fenitrothion (FNT) and chlorpyrifos-methyl (CLT) using a photonic suspension array based on silica colloidal crystal beads (SCCBs). The SCCBs were encoded with the characteristic reflection peak originating from the stop-band of colloidal crystal. This approach avoids the bleaching, fading or potential interference seen when encoding by fluorescence. SCCBs with a nanopatterned surface had increased biomolecule binding capacity and improved stability. Under optimal conditions, the proposed suspension array allowed simultaneous detection of the selected pesticides in the ranges of 0.25 to 1024 ng/mL and 0.40 to 735.37 ng/mL, with the limits of detection (LODs) of 0.25 and 0.40 ng/mL, respectively. The suspension array was specific and had no significant cross-reactivity with other chemicals. The mean recoveries in tests in which samples were spiked with target standards were 82.35% to 109.90% with a standard deviation within 9.93% for CLT and 81.64% to 108.10% with a standard deviation within 8.82% for FNT. The proposed method shows a potentially powerful capability for fast quantitative analysis of pesticide residues.
منابع مشابه
Development a HPLC method for simultaneous determination of Azinphose methyl, Diazinon, Phosalone and Chlorpyrifos residues in fruit
A high-performance liquid chromatography with ultraviolet detection (HPLC/UV) methodwhich was used solid-phase extraction for cleanup, was developed for the determination ofAzinphos methyl ,Phosalone, Diazinon and Chlorpyrifos residues in fruits. A full factorialexperimental design was used for development of HPLC condition and evaluation of effect ofthree factors (pH of mobile phase, percent o...
متن کاملMultiplex Detection of B-Type Natriuretic Peptide, Cardiac Troponin I and C-Reactive Protein with Photonic Suspension Array
A novel photonic suspension array has been developed for multiplex immunoassay. The carriers of this array were silica colloidal crystal beads (SCCBs). The codes of these carriers have characteristic reflection peaks originating from their structural periodicity; therefore they do not suffer from fading, bleaching, quenching or chemical instability. In addition, the fluorescence background of S...
متن کاملHealth risk assessment of selected pesticide residues in locally produced vegetables of Bangladesh
Consumption of pesticide contaminated vegetables pose a major threat to public health. High Performance Liquid Chromatography (HPLC) with a Photo Diode Array detector (PDA) was used to determine two organochlorines (methoxychlor and DDT), seven organophosphorus (acephate, chlorpyrifos, fenthion, fenitrothion, malathion, parathion, and ethion), two carbamate (carbaryl and carbofuran) and one pyr...
متن کاملToxic Action Data for the Mixture of Concern and Component Mixtures
This chapter provides a review and evaluation of the literature pertinent to joint toxic action of the mixture and its components. 2.1 Mixture of Concern Toxicological data or PBPK models were not available for the complete mixture of concern. Toxicological and mechanistic data, but no PBPK models, were available for all of the binary mixtures, but were limited. For some binary mixtures, few or...
متن کاملDetermination of insecticides in honey by matrix solid-phase dispersion and gas chromatography with nitrogen-phosphorus detection and mass spectrometric confirmation.
A multiresidue method was developed for the determination of 12 organophosphorus insecticides (diazinon, parathion methyl, fenitrothion, pirimiphosmethyl, malathion, fenthion, chlorpyrifos, quinalphos, methidathion, ethion, azinphosmethyl, coumaphos), one carbamate (pirimicarb), and one amidine (amitraz) in unifloral and multifloral honeys. The analytical procedure was based on the matrix solid...
متن کامل