A blood sampling microsystem for pharmacokinetic applications: design, fabrication, and initial results.
نویسندگان
چکیده
This paper describes a microsystem for automated blood sampling from laboratory mice used in pharmacokinetic studies. Intended to be mounted as a "backpack" on a mouse, it uses a microneedle, reservoir, and an actuator to instantaneously prick the animal for a time-point sample, eliminating the need for a tethered catheter with large dead volume. The blood is collected by capillary effect through a 31-33 gauge microneedle (250-210 microm OD) into a approximately 1 microL micromachined steel reservoir. The voice coil actuator provides a peak force of approximately 300 mN, which amply exceeds the measured piercing force of mouse skin (i.e., 60-85 mN for a 31-gauge needle with 12 degrees bevel). The sampling system was tested in vitro using a mock vessel with adjustable pressure; the reservoir was filled in <0.15 s by a combination of the capillary effect and blood pressure. The system may also be used to sample interstitial fluid, but the absence of blood pressure makes it necessary to enhance the capillary effect of the needle. This is accomplished by either electropolishing the inner surface to make it more hydrophilic or using a polymer wire insert to increase the surface area. The steel surface of the reservoir is also coated with silicon oxynitride by plasma-enhanced chemical vapor deposition to improve its hydrophilicity. Blood from fresh bovine tissue was collected into the reservoir to simulate interstitial fluid sampling. In vivo tests on live, anesthetized mice resulted in successful collection of blood into the reservoir. The possible integration of the device in microanalytical systems and the device scalability for multisampling are discussed.
منابع مشابه
بیواکی وین: نرم افزاری برای مطالعات هم ارزی زیستی
Abstract Introduction: Bioequivalence studies are the most important way of evaluating the quality and efficacy of pharmaceutical formulations. In a bioequivalence study, the rate and extent of drug absorption into the general circulation is measured and the pharmacokinetic parameters should be calculated and statistically evaluated for the reference and test products. Pharmacokinetic paramete...
متن کاملTHE EFFECTS OF INITIAL SAMPLING AND PENALTY FUNCTIONS IN OPTIMAL DESIGN OF TRUSSES USING METAHEURISTIC ALGORITHMS
Although Genetic algorithm (GA), Ant colony (AC) and Particle swarm optimization algorithm (PSO) have already been extended to various types of engineering problems, the effects of initial sampling beside constraints in the efficiency of algorithms, is still an interesting field. In this paper we show that, initial sampling with a special series of constraints play an important role in the conv...
متن کاملA Short Review on Fabrication Methods of Micro-Cantilever for Ionic Electroactive Polymer Sensors/Actuators
Micro-electroactive polymers have wide applications from industry to healthcare. Artificial muscles, microvalves, microswitches, haptic sensing, blood pressure and pulse monitoring are some potential applications for micro-electroactive polymers. The most advantage of micro-electroactive polymers as sensors and actuators is bio-compatibility and low power threshold for large deformations...
متن کاملDesign and Fabrication of a Microwave Weed Killer Device for Weed Control Applications
In this paper, the design and the results of a microwave radiation system for agriculture applications is discussed. The system is fabricated and successfully tested on weed seeds. The device, which uses a commercial 1 kW magentron, proved to be effective for preventing the germination control of popular weeds of Iran. Seven weed species were tested separately by using this system and then the ...
متن کاملBiofunctionalization of Gold Nanorods: A Comparative Study on Conjugation Methods for Fabrication of Nanobiosensors
Gold Nanorods have promised variety of applications in biomedicine and biosensing. As a fruitful candidate for early detection and imaging, these plasmonic nanoparticles have been utilized for diagnostic applications of interest. However, prior to design and fabricate SPR-based nanobiosensors, the type and nature of conjugation with biomolecules would be of utmost importance. Herein, four strat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 9 24 شماره
صفحات -
تاریخ انتشار 2009