Dynamic hip screw fixation of intertrochanteric fractures without using traction table.

نویسندگان

  • S Kumar
  • G N Chadha
چکیده

To evaluate a new technique of Dynamic hip screw (DHS) fixation without using traction table. From july 2006 to july 2012, 328 patients undergoing DHS fixation using manual traction technique were evaluated in terms of Tip apex distance (TAD), -quality of fracture reduction, operation time, preoperative preparation time. In 97% cases good to moderate reduction could be achieved. The mean TAD was 19.2 millimeters, mean operation time 37 minutes and screw cutout rate was only 0.91%. This technique is easy, reproducible, cheap do not sacrifice reduction alignment, screw position and is extremely beneficial in polytrauma patients where multiple surgeries are to be done.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Results of Intertrochanteric Fractures Fixed with Dynamic Hip Screw Fixation

Numerous internal fixation devices have been used to stabilize intertrochanteric fracturesWe have analyzed the results of the intertrochanteric fractures treated with dynamic hip screw fixation. 33 patients (13 males, 20 females) were included. Range of age was 50-90 years, right side involved in 21 cases whereas left side in 12 cases and classified according to Boyd and griffin classification ...

متن کامل

A double-blind, prospective, randomised, controlled clinical trial of minimally invasive dynamic hip screw fixation of intertrochanteric fractures.

OBJECTIVE To compare minimally invasive dynamic hip screw (MIDHS) fixation with conventional dynamic hip screw (CDHS) fixation for treatment of intertrochanteric femoral fracture. METHODS Of the 66 participants in this double-blind study, 35 were randomised to MIDHS and 31 to CDHS fixation. Main outcome measurements were wound size, haemoglobin decrease, blood transfusion rate, pain score, an...

متن کامل

Frequency and Causes of Failure of Dynamic Hip Screw Fixation for Interochanteric Fracture

Background: Hip fractures are a leading cause of death and disability among elderly. Approximately half of these injuries are intertrochanteric fractures and the incidence is continuously increasing. It is estimated that the incidence of intertrochanteric fractures will be doubled by the year 2040. Different types of implants were tried at different times for internal fixation of these fracture...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 82 2  شماره 

صفحات  -

تاریخ انتشار 2016