Xpert MTB/RIF test performance assay in respiratory samples at real work settings in a developing country.
نویسندگان
چکیده
INTRODUCTION The Xpert MTB/RIF test detects DNA from Mycobacterium tuberculosis complex and susceptibility to rifampin. It has been evaluated repeatedly under "ideal" conditions including centrifugation of sputum and bronchoalveolar lavage, Ziehl Neelsen (ZN) and auramine/rhodamine staining, as well as with solid and liquid automated culture methods. Results from such evaluations cannot be extrapolated to low-income countries that do not routinely use all these processes. OBJECTIVE To assess the performance of the Xpert MTB/RIF test in respiratory samples under "real" conditions of work in a low-income country and its correlation with phenotypic susceptibility testing. MATERIALS AND METHODS We conducted a cross-sectional study to assess the performance of the Xpert MTB/RIF test in =12 year-old patients with suspected pulmonary tuberculosis. In routine sample processing at the Hospital we do not use sputum centrifugation, staining with auramine/rhodamine or automated liquid culture. RESULTS We screened 152 patients of whom 108 were eligible for the study and 103 were included in the analysis; 34% of the samples were positive. The overall test sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 91%, 92%, 83% and 96%, respectively. In ZN-negative samples the sensitivity, specificity, PPV and NPV were 87%, 91%, 68% and 97%, respectively. The results of sensitivity and resistance to rifampin were concordant with susceptibility testing using the multiple proportions method (kappa=1, p<0.0001). CONCLUSIONS The Xpert MTB/RIF test overall performance was similar to the one achieved under ideal conditions. Its performance in ZN-negative samples was better under "real" conditions of work in a low-income country.
منابع مشابه
Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia
OBJECTIVES To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods: This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Ri...
متن کاملRapid and Accurate Detection of Mycobacterium tuberculosis in Sputum Samples by Cepheid Xpert MTB/RIF Assay—A Clinical Validation Study
BACKGROUND A crucial impediment to global tuberculosis control is the lack of an accurate, rapid diagnostic test for detection of patients with active TB. A new, rapid diagnostic method, (Cepheid) Xpert MTB/RIF Assay, is an automated sample preparation and real-time PCR instrument, which was shown to have good potential as an alternative to current reference standard sputum microscopy and cultu...
متن کاملAccuracy of different Xpert MTB/Rif implementation strategies in programmatic settings at the regional referral hospitals in Uganda: Evidence for country wide roll out
BACKGROUND Xpert MTB/RIF assay is a highly sensitive test for TB diagnosis, but still costly to most low-income countries. Several implementation strategies instead of frontline have been suggested; however with scarce data. We assessed accuracy of different Xpert MTB/RIF implementation strategies to inform national roll-out. METHODS This was a cross-sectional study of 1,924 adult presumptive...
متن کاملRapid diagnosis of tuberculosis using Xpert MTB/RIF assay - Report from a developing country
OBJECTIVE To evaluate the diagnostic accuracy of the Xpert MTB/RIF assay for the detection of M. tuberculosis in pulmonary and extrapulmonary specimens and to compare it with conventional techniques. METHODS During a period of 10 months from December 2012 through September 2013, two hundred and forty five clinically TB suspects were enrolled for Xpert MTB\RIF assay. The cohort comprised of 20...
متن کاملPerformance of real-time PCR Xpert ®MTB/RIF in diagnosing extrapulmonary tuberculosis.
The real time PCR Xpert ® MTB/RIF is fundamental for rapid diagnosis in paucibacillary respiratory samples and for the detection of multidrug-resistant TB cases. This paper aimed to determine its performance on different extrapulmonary samples. We determined sensitivity, specificity, positive and negative predictive value on respiratory and non-respiratory samples collected from January 2010 to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedica : revista del Instituto Nacional de Salud
دوره 35 1 شماره
صفحات -
تاریخ انتشار 2015