High-pressure fluorescence correlation spectroscopy.
نویسندگان
چکیده
We demonstrate that a novel high-pressure cell is suitable for fluorescence correlation spectroscopy (FCS). The pressure cell consists of a single fused silica microcapillary. The cylindrical shape of the capillary leads to refraction of the excitation light, which affects the point spread function of the system. We characterize the influence of these beam distortions by FCS and photon-counting histogram (PCH) analysis and identify the optimal position for fluorescence fluctuation experiments in the capillary. At this position within the capillary, FCS and photon-counting histogram experiments are described by the same equations as used in standard FCS experiments. We report the first experimental realization of fluorescence fluctuation spectroscopy under high pressure. A fluorescent dye was used as a model system for evaluating the properties of the capillary under pressure. The autocorrelation function and the photon count distribution were measured in the pressure range from 0 to 300 MPa. The fluctuation amplitude and the diffusion coefficient show a small pressure dependence. The changes of these parameters, which are on the order of 10%, are due to the pressure changes of the viscosity and the density of the aqueous medium.
منابع مشابه
Comparison of different fluorescence fluctuation methods for their use in FRET assays: monitoring a protease reaction.
We compare the accuracy of a variety of Fluorescence Fluctuation Spectroscopy (FFS) methods for the study of Förster Resonance Energy Transfer (FRET) assays. As an example, the cleavage of a doubly labeled, FRET-active peptide substrate by the protease Trypsin is monitored and analyzed using methods based on fluorescence intensity, Fluorescence Correlation Spectroscopy (FCS) and Fluorescence In...
متن کاملHigh-efficiency single molecule fluorescence detection and correlation spectroscopy with dielectric microspheres
Microspheres made of high refractive index melamine resin are shown to enhance the fluorescence from single molecules in solution by seven-fold, and simultaneously reduce the observation volume by thirteen-fold, as compared to state-of-the-art confocal microscopy. This fluorescence enhancement is demonstrated to dramatically increase the signal-to-noise ratio in fluorescence correlation spectro...
متن کاملIntracellular applications of fluorescence correlation spectroscopy: prospects for neuroscience.
Based on time-averaging fluctuation analysis of small fluorescent molecular ensembles in equilibrium, fluorescence correlation spectroscopy has recently been applied to investigate processes in the intracellular milieu. The exquisite sensitivity of fluorescence correlation spectroscopy provides access to a multitude of measurement parameters (rates of diffusion, local concentration, states of a...
متن کاملPin-hole array correlation imaging: highly parallel fluorescence correlation spectroscopy.
In this work, we describe pin-hole array correlation imaging, a multipoint version of fluorescence correlation spectroscopy, based upon a stationary Nipkow disk and a high-speed electron multiplying charged coupled detector. We characterize the system and test its performance on a variety of samples, including 40 nm colloids, a fluorescent protein complex, a membrane dye, and a fluorescence fus...
متن کاملConcepts in Fluorescence Correlation Spectroscopy
Fluorescence Correlation Spectroscopy (FCS) and related techniques are becoming widely used to measure molecular dynamics in a broad variety of specimens. These techniques provide important quantitative information on dynamics -such as diffusion coefficients, local concentration, binding reactions under equilibrium conditionswith high spatial and temporal resolutions. Also, they are minimal inv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biophysical journal
دوره 85 4 شماره
صفحات -