Improved emission tomography via multiscale sinogram analysis

نویسندگان

  • Klaus E. Timmermann
  • Robert D. Nowak
  • Keith J. Jones
چکیده

In this paper, we extend a multiscale Bayesian approach to modeling and estimation of general Poisson processes previously developed in [1] by the first two authors, and apply it to the emission computed tomography (ECT) image reconstruction problem. We develop a practical prior model for the sinogram image, which we use to estimate the underlying sinogram intensity from the raw projection data prior reconstruction. This sinogram estimate is then used in conjunction with the standard filtered-backprojection algorithm to produce an improved image reconstruction. The impact of the new filtering approach on ECT imaging is illustrated with simulated and clinical data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-Dose Dual-Energy Computed Tomography for PET Attenuation Correction with Statistical Sinogram Restoration

Dual-energy (DE) X-ray computed tomography (CT) has been proposed as an useful tool in various applications. One promising application is DECT with low radiation doses used for attenuation correction in positron emission tomography (PET). In low-dose DECT, conventional methods for sinogram decomposition have been based on logarithmic transformations and ignored noise properties, leading to very...

متن کامل

SPECT reconstruction with sub-sinogram acquisitions

Described herein are the advantages of using sub-sinograms for single photon emission computed tomography image reconstruction. A sub-sinogram is a sinogram acquired with an entire data acquisition protocol, but in a fraction of the total acquisition time. A total-sinogram is the summation of all sub-sinograms. Images can be reconstructed from the total-sinogram or from sub-sinograms and then b...

متن کامل

SNR-weighted Sinogram Smoothing with Improved Noise-resolution Properties for Low-dose X-ray Computed Tomography

To treat the noise in low-dose x-ray CT projection data more accurately, analysis of the noise properties of the data and development of a corresponding efficient noise treatment method are two major problems to be addressed. In order to obtain an accurate and realistic model to describe the x-ray CT system, we acquired thousands of repeated measurements on different phantoms at several fixed s...

متن کامل

Region-Based Partial Volume Correction Techniques for PET Imaging: Sinogram Implementation and Robustness

Background/Purpose. Limited spatial resolution of positron emission tomography (PET) requires partial volume correction (PVC). Region-based PVC methods are based on geometric transfer matrix implemented either in image-space (GTM) or sinogram-space (GTMo), both with similar performance. Although GTMo is slower, it more closely simulates the 3D PET image acquisition, accounts for local variation...

متن کامل

Research and applications: Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET

BACKGROUND AND OBJECTIVE Combined magnetic resonance/positron emission tomography (MR/PET) is a relatively new, hybrid imaging modality. MR-based attenuation correction often requires segmentation of the bone on MR images. In this study, we present an automatic segmentation method for the skull on MR images for attenuation correction in brain MR/PET applications. MATERIALS AND METHODS Our met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999