Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong.

نویسندگان

  • H Guo
  • S C Lee
  • L Y Chan
چکیده

To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM(10) (particulate matters with aerodynamic diameter less than 10 microm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO(2)) and sulfur dioxide (SO(2)). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM(10), TBC, CO and NO(2) at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM(10) and TBC. The elevated PM(10) concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM(10) concentration at poultry stalls was higher than the HKIAQO standard of 180 microg/m(3), and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m(3), which was above the HKIAQO standard of 1000 CFU/m(3). The bacteria levels at other three stalls were all below the HKIAQO standard. Statistical analysis indicated that there were no significant differences among the four stalls for CO, NO(x) and SO(2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening for Indoor Air Quality Express Assessment Protocol of Air-conditioned Offices

A successful Indoor Air Quality (IAQ) surveillance plan is essential for healthy and safe workplaces; yet it is costly to sample all air pollutants of the entire community. In Hong Kong, a voluntary IAQ certification scheme for workplaces proposes the acceptable concentration levels of nine common indoor air pollutants, namely carbon dioxide (CO2), carbon monoxide (CO), respirable suspended par...

متن کامل

Design of Air Distribution System for Operation Theatre Using Flow Visualization Techniques to Improve Flow Characteristics

Operation Theatre (OT) is the most important area where precise controlled on indoor air quality is required because it is directly related to patient health and its recovery period. This work aims to study and visualize the airflow distribution of conventional flat air diffuser ventilation system and newly designed angular air ventilation system in OT. Angular Air Distribution (AAD) system is ...

متن کامل

Outdoor-indoor air pollution in urban environment: challenges and opportunity

*Correspondence: Dennis Y. C. Leung, Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, Hong Kong e-mail: [email protected] With the continual improvement in our quality of life, indoor air quality has become an important area of concern in the twenty-first century. Indoor air quality is affected by many factors including the type and running conditions of indoor polluti...

متن کامل

Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening

Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-eff...

متن کامل

Submission to the Subcommittee on Issues Relating to Air , Noise and Light Pollution on " Air Pollution Modelling in Hong Kong

We welcome the Subcommittee’s review of “Air Pollution Modelling in Hong Kong”. Hong Kong’s air quality is a topic of great public concern. The lack of progress in improving air quality has led many to question the effectiveness of our air quality management system. Most people understand that air quality modelling is important for our air quality management system because of its role in air qu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Science of the total environment

دوره 323 1-3  شماره 

صفحات  -

تاریخ انتشار 2004