Exeter small femoral stem for patients with small femurs.

نویسندگان

  • Kwok-hing Chiu
  • Kin-wing Cheung
  • Kwong-yin Chung
  • Wan-yiu Shen
چکیده

PURPOSE To report the long-term results of total hip arthroplasty (THA) using small size Exeter femoral stems. METHODS Eight men and 34 women aged 60 to 83 (mean, 70) years underwent 45 THAs using the Exeter small stem with offsets of 30 mm (n=3), 33 mm (n=15), and 35.5 mm (n=27). The Harris hip score was assessed pre- and post-operatively. Stem alignment and axial subsidence of the stem were measured. Radiolucent lines around the femur were recorded at 14 Gruen zones. Completeness and thickness of the cement mantle and cement fractures were also noted. Ectopic ossification, if present, was graded. Stem loosening was based on the Olsson definitions. RESULTS The mean follow-up was 9 (range, 5-12) years. The mean Harris hip score improved from 37 (range, 13-61) to 80 (range, 47-96) [p<0.001]. At the latest follow-up, the score was excellent (90-100) in 8 (18%) of the hips, good (80-89) in 21 (47%), fair (70-79) in 9 (20%), and poor (<70) in 7 (16%). All hips had a complete cement mantle of 2 mm or more. All stems were inserted without intramedullary reaming. 11 (24%) of the hips developed stem subsidence of <2 mm; all stabilised within 2 years. None of these patients had pain or other radiological signs of loosening. Six stems showed radiolucent lines of <1 mm in the upper zones, which were not progressive. No cement fracture or subsidence was noted. Using revision for any cause as an endpoint, the overall survival rate of Exeter small femoral stem was 100% at 10 years and 89% at 12 years. CONCLUSION The results of Exeter small stems for patients with small femurs are good.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The threshold force required for femoral impaction grafting in revision hip surgery

BACKGROUND AND PURPOSE Femoral impaction grafting requires vigorous impaction to obtain adequate stability without risk of fracture, but the force of impaction has not been determined. We determined this threshold force in a preliminary study using animal femurs. METHODS Adult sow femurs were used because of their morphological similarity to human femurs in revision hip arthroplasty. 35 sow f...

متن کامل

Design-related risk factors for revision of primary cemented stems

BACKGROUND AND PURPOSE Even small design variables of the femoral stem may influence the outcome of a hip arthroplasty. We investigated whether design-related factors play any role in the risk of non-aseptic revision of the 3 most frequently used primary cemented stem designs in the Swedish Hip Arthroplasty Register. PATIENTS AND METHODS We studied 71,184 primary cemented femoral stem implant...

متن کامل

The Exeter femoral stem continues to migrate during its first decade after implantation

BACKGROUND Due to its collarless, double-tapered polished design, the Exeter femoral stem is known to migrate distally in the first 5 years after implantation. However, its long-term migration pattern has not been investigated. PATIENTS AND METHODS 39 consecutive patients (41 total hip arthroplasties) received a cemented Exeter stem and had prospective clinical and RSA follow-up. Patients wer...

متن کامل

Defining the impaction frequency and threshold force required for femoral impaction grafting in revision hip arthroplasty

BACKGROUND AND PURPOSE The two most common complications of femoral impaction bone grafting are femoral fracture and massive implant subsidence. We investigated fracture forces and implant subsidence rates in embalmed human femurs undergoing impaction grafting. The study consisted of two arms, the first examining the force at which femoral fracture occurs in the embalmed human femur, and the se...

متن کامل

Small and similar amounts of micromotion in an anatomical stem and a customized cementless femoral stem in regular-shaped femurs

BACKGROUND AND PURPOSE High primary stability is important for long-term survival of uncemented femoral stems. Different stem designs are currently in use. The ABG-I is a well-documented anatomical stem with a press-fit design. The Unique stem is designed for a tight customized fit to the cortical bone of the upper femur. This implant was initially developed for patients with abnormal anatomy, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2011