Intraoperative pedography: a validated method for static intraoperative biomechanical assessment.

نویسندگان

  • Martinus Richter
  • Michael Frink
  • Stefan Zech
  • Nicolas Vanin
  • Jens Geerling
  • Patrizia Droste
  • Christian Krettek
چکیده

BACKGROUND A new device was developed to perform intraoperative static pedography. The purpose of this study was to validate the introduced method by a comparison with the standard method for dynamic and static pedography. METHODS A device known as Kraftsimulator Intraoperative Pedographie (KIOP) was developed for intraoperative placement of standardized forces to the sole of the foot. Pedographic measurements were done with a custom-made mat that was inserted into the KIOP (Pliance, Novel Inc., St. Paul, MN, USA). Validation was done in two steps: (1) comparison of standard dynamic pedography walking on a platform, standard static pedography in standing on a platform, and pedography with KIOP in supine position in 30 healthy volunteers, and (2) comparison of static pedography in standing position, pedography with KIOP supine awake, and pedography with KIOP supine with 30 patients under anesthesia. Individuals who had operative procedures at the knee or distal to the knee were excluded. The different measurements were compared (one-way ANOVA, t-test; significance level 0.05). RESULTS No significant differences were found among all measurements for the hindfoot compared to midfoot-forefoot force distribution. For the medial compared to lateral force distribution and the 10-region-mapping, significant differences were found when comparing all measurements (steps 1 and 2) and when comparing the measurements of step 1 only. No differences were found for these distributions when comparing the measurements of step 2 alone or when comparing the measurements of step 1 and 2 without the platform measurements of step 1 (dynamic walking pedography and static standing pedography). No significant differences in the force distributions were found in step 2 when comparing subjects without anesthesia, with general anesthesia, and with spinal anesthesia. CONCLUSIONS The KIOP device allows a valid static intraoperative pedography measurement. No statistically significant force distribution differences were found between standing subjects and anesthetized subjects in the supine position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative pedography – development, validation and clinical use of a novel method for intraoperative biomechanical assessment

Methods Development For an intraoperative introduction of standardized forces to the footsole, a device named Kraftsimulator Intraoperative Pedographie (KIOP, manufactured by the Workshop of the Hannover Medical School, Hannover, Germany; Registered Design No. 2

متن کامل

Computer-Assisted Surgery (CAS) in Foot and Ankle Surgery

Foot and ankle surgery at the end of the twentieth century was characterized by the use of sophisticated computerized preoperative and postoperative diagnostic and planning procedures.13,39 However, intraoperative computerized tools that assist surgeons during their struggle for the planned optimal operative result are lacking. This results in an intraoperative “black box” without optimal visua...

متن کامل

اعتبارسنجی سر شتاب‌دهندۀ پرتودرمانی حین عمل‌ جراحی LIAC با استفاده از روش مونت‌کارلو

With the development of science and technology in the medical field and need more than ever to accuracy and quality of treatment has been causer increase different radiotherapy methods. Almost the past two decade’s intraoperative radiation therapy (IORT) as one of the new techniques used to treat cancer patients. One of the problems with this method is obtaining accurate dosimetry, becaus...

متن کامل

ارزیابی قابلیت پیشگویی هماچوری حین عمل جراحی اسلینگ ساب اورترال برای پارگی دیواره مثانه در زنان با بی‌اختیاری ادراری

    Background & Aim: Bladder wall perforation is one of important complications in suburethral sling procedures. The aim of the present study is to assess predictive value of intraoperative   hematuria for bladder rupture caused by passing tunnlers during suburethral sling.Patients and Method: 250 females with stress urinary incontinence were enrolled in this cross-sectional study from October...

متن کامل

Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle international

دوره 27 10  شماره 

صفحات  -

تاریخ انتشار 2006