Forced-air warming devices and the risk of surgical site infections.
نویسندگان
چکیده
The potential that forced-air warming systems may increase the risk of surgical site infections (SSIs) by acting as a vector or causing unwanted airflow disturbances is a concern to health care providers. To investigate this potential, we examined the literature to determine whether forced-air warming devices increase the risk of SSIs in patients undergoing general, vascular, or orthopedic surgical procedures. We examined 192 evidence sources, 15 of which met our inclusion criteria. Most sources we found indirectly addressed the issue of forced-air warming and only three studies followed patients who were warmed intraoperatively with forced-air warming devices to determine whether there was an increased incidence of SSIs. All of the sources we examined contained methodological concerns, and the evidence did not conclusively suggest that the use of forced-air warming systems increases the risk of SSIs. Given the efficacy of these devices in preventing inadvertent perioperative hypothermia, practitioners should continue to use and clean forced-air warming systems according to the manufacturer's instructions until well-conducted, large-scale trials can further examine the issue.
منابع مشابه
ARTHROPLASTY Do forced air patient - warming devices disrupt unidirectional downward airflow ?
J Bone Joint Surg Br 2012;94-B:254–6. Received 7 June 2011; Accepted after revision 14 September 2011 Patient warming significantly decreases the risk of surgical site infection. Recently there have been concerns that forced air warming may interfere with unidirectional airflow, potentially posing an increased risk of infection. Our null hypothesis was that forced air and radiant warming devic...
متن کاملDo forced air patient-warming devices disrupt unidirectional downward airflow?
Patient warming significantly decreases the risk of surgical site infection. Recently there have been concerns that forced air warming may interfere with unidirectional airflow, potentially posing an increased risk of infection. Our null hypothesis was that forced air and radiant warming devices do not increase the temperature and the number of particles over the surgical site when compared wit...
متن کاملSafety and efficacy of resistive polymer versus forced air warming in total joint surgery
BACKGROUND Forced-air warming is used as a mechanism to prevent hypothermia and adverse outcomes associated with hypothermia among patients undergoing surgery. Patient safety in healthcare includes the use of devices and technology that minimize potential adverse events to patients. The present study sought to compare the capabilities of patient warming between two different devices that use di...
متن کاملForced-air warming and ultra-clean ventilation do not mix: an investigation of theatre ventilation, patient warming and joint replacement infection in orthopaedics.
We investigated the capacity of patient warming devices to disrupt the ultra-clean airflow system. We compared the effects of two patient warming technologies, forced-air and conductive fabric, on operating theatre ventilation during simulated hip replacement and lumbar spinal procedures using a mannequin as a patient. Infection data were reviewed to determine whether joint infection rates were...
متن کاملPatient warming excess heat: the effects on orthopedic operating room ventilation performance.
BACKGROUND Patient warming has become a standard of care for the prevention of unintentional hypothermia based on benefits established in general surgery. However, these benefits may not fully translate to contamination-sensitive surgery (i.e., implants), because patient warming devices release excess heat that may disrupt the intended ceiling-to-floor ventilation airflows and expose the surgic...