The cornea is not a piece of plastic.

نویسندگان

  • V Stoy
  • M Fernandes
چکیده

To the Editor: In her recent editorial (Roberts C. The cornea is not a piece of plastic. J Refract Surg 2000;16:407-413), Dr. Roberts points out that biomechanical flattening enhances a myopic excimer laser ablation and works against a hyperopic ablation. Would the circular severing of corneal lamellae in hyperopic ablation not lead to a contraction of the central part of these lamellae with a heaping up of tissue? This effect could compensate for the flattening by the peripheral pull or even exceed it. One might also argue that central islands in myopic ablation seem to contradict an additional central flattening effect. To the Editor: We congratulate Cynthia Roberts for her editorial , " The Cornea Is Not a Piece of Plastic. " Besides high frequency ultrasound, Orbscan topography, and pachymetry data, there is also direct histologi-cal evidence 1 for the paradoxical addition of stromal tissue outside the ablation zone. In a study on his-tologic changes after +10 D hyperopic PRK on rabbit corneas, we found stromal thickening on the order of 20 µm on the shoulder and in the center of the treatment. However, we have questions about the proposed mechanism of flattening of this peripheral swelling. There is no doubt that the swelling of the " sponges " goes in the direction of the least resistance, which is outward. This swelling itself of the peripheral superficial cornea without any change in curvature of the posterior corneal surface, is sufficient to cause central flattening. The possibility proposed by Roberts—that the swelling due to the cross-linking pulls outward and laterally on the center and flattens it both anteriorly and posteriorly (Fig 4 in Roberts editorial)—is not necessary and not supported by posterior corneal surface Orbscan data. Indeed, two Orbscan studies after PRK 2,3 suggest the opposite effect: a central outward bulging of the posterior corneal stroma to steepen both the anterior and posterior corneal curvatures. We think, 1) that the swelling causes flattening of the anterior surface merely by tissue " addition, " and 2) that the central thinning causes a discrete pro-trusion of the posterior surface counteracted and overridden by the first mechanism (and the abla-tion) on the anterior surface, and 3) that in the case of hyperopic correction, the central swelling may enhance the optical effect instead of causing regression. We agree with the conclusion that the first step is to gain a better understanding of the corneal bio-mechanical …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manufacturing of Aluminum Thin Cylindrical Parts By Using Friction Stir Welding Method

Recently friction stir welding for manufacturing of welded tubes has been developed. Friction stir welding is a continuous solid state welding process in which a non-consumable rotating tool using severe plastic deformation Can join materials can be join materials. Commonly, a portion of a specially shaped rotating tool is plunged between metalsjoint cross section and adjacent faces of the join...

متن کامل

Manufacturing of Aluminum Thin Cylindrical Parts By Using Friction Stir Welding Method

Recently friction stir welding for manufacturing of welded tubes has been developed. Friction stir welding is a continuous solid state welding process in which a non-consumable rotating tool using severe plastic deformation Can join materials can be join materials. Commonly, a portion of a specially shaped rotating tool is plunged between metalsjoint cross section and adjacent faces of the join...

متن کامل

The Effect of Lyophilization on Light Transmission of Amniotic Membrane: A Comparison with Rabbit Cornea

Background & Aims: Amniotic membrane persists for a long time after ocular transplantation (as corneal substitute) and can affect light transmission (transparency). The aim of this study was to evaluate the transparency of amniotic membrane after freeze-drying (lyophilization) and to compare the results with transparency of rabbit cornea. Methods: Transparency of rabbits’ corneas and fresh and ...

متن کامل

Effects of the longitudinal and lateral axlebox clearance on hunting, curving and wear behavior of the three piece bogies

Three piece bogies are widely in use by the freight railway services throughout the world. In comparison with the other freight bogies they cost less and are easier to maintain. However, they do not exhibit favorable curving behavior. Amongst the methods to improve the bogie performance is the proposal to introduce lateral clearance in the bogies’ axleboxs. In the case of the three piece bogies...

متن کامل

Case report of a piece of dishwashing steel wool in a child’s pharynx

Objective: Foreign body swallowing is a common pediatric problem. A foreign body in the pharynx is a medical emergency that requires urgent intervention. Evaluation and treatment of pharyngeal foreign bodies is much more difficult in children than in adults and sometimes requires hospitalization and removal of the foreign bodies under general anesthesia due to children’s lack of cooperation. Fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2000