Design of a Novel Front-End Readout ASIC for PET Imaging System

نویسندگان

  • Huiming Zeng
  • Tingcun Wei
  • Linkai Shen
  • Wu Gao
چکیده

The architecture of a multi-channel front-end system is important for realizing a high-resolution PET system. We propose a novel front-end readout electronic system with TDC to deal with time information for PET system which can easily design the timing control. Each channel consists of a charge preamplifier, slow/fast shaper, discriminator and a analog memory. There are a ADC and a TDC to process the energy information and time information for each channel at the same time. In this paper, the whole system signals flow is all simulated by MATLAB. The simulation results show that the proposed system can process slender current from the detector and achieve the energy and time information. The proposed architecture can be applied to high-resolution PET imaging systems with multi-channel ASICs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

9.4–14.1 T small-animal PET-MR imaging: Feasibility analysis of LYSO APD readout via long signal lines

In the present work we intend to assess the readout feasibility of Avalanche Photodiode (APD) detectors via long signal lines for the development of a combined small-animal PET-MR prototype based on the ClearPEM technology. The detection performance of a LYSO-APD module was evaluated reading out the APD charge signals to the front-end ASIC via an 80 mm length flexible flat-cable (FFC). Experime...

متن کامل

ASYNCHRONOUS FRONT-END ASIC FOR X-RAY MEDICAL IMAGING APPLICATIONS IMPLEMENTED IN CMOS 0.18μm TECHNOLOGY

An idea as well as a CMOS implementation of the novel multi-channel readout front-end ASIC for nuclear X-ray imaging system has been presented in the paper. The circuit has been designed in an example configuration with eight equal channels, but the modular structure enables an easy realization of larger systems with even hundreds of channels. Various new circuit solutions have been proposed by...

متن کامل

A Low Time Pulse Processing Analysis for DOI Pet

Heartbeat shape-discriminator (PSD) has been used all through the past 40 years in radiation area structures reaching out from remedial demonstrative imaging cams to high imperativeness material science. The limit of PSD is to partitioned radiation signs in perspective of particular sign shape. It can be used to perceive the sparkle sort in (Depth of affiliation) DOI PET application, where the ...

متن کامل

Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

University of Texas MD Anderson Cancer Center, USA It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-s...

متن کامل

A Serializer ASIC at 5 Gbps for Detector Front-end Electronics Readout

Optical data links are used in detector front-end electronics readout systems of experiments in the Tevatron and the LHC. Optical links in high energy particle physics experiments usually have special requirements such as radiation tolerance, ultra high reliability and low power dissipation. These requirements are often not met by commercial components which are designed for applications in non...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013