Progression to chronic atrial fibrillation after pacing: the Canadian Trial of Physiologic Pacing. CTOPP Investigators.
نویسندگان
چکیده
OBJECTIVES This study examined the effect of physiologic pacing on the development of chronic atrial fibrillation (CAF) in the Canadian Trial Of Physiologic Pacing (CTOPP). BACKGROUND The role of physiologic pacing to prevent CAF remains unclear. Small randomized studies have suggested a benefit for patients with sick sinus syndrome. No data from a large randomized trial are available. METHODS The CTOPP randomized patients undergoing first pacemaker implant to ventricular-based or physiologic pacing (AAI or DDD). Patients who were prospectively found to have persistent atrial fibrillation (AF) lasting greater than or equal to one week were defined as having CAF. Kaplan-Meier plots for the development of CAF were compared by log-rank test. The effect of baseline variables on the benefit of physiologic pacing was evaluated by Cox proportional hazards modeling. RESULTS Physiologic pacing reduced the development of CAF by 27.1%, from 3.84% per year to 2.8% per year (p = 0.016). Three clinical factors predicted the development of CAF: age > or =74 years (p = 0.057), sinoatrial (SA) node disease (p < 0.001) and prior AF (p < 0.001). Subgroup analysis demonstrated a trend for patients with no history of myocardial infarction or coronary disease (p = 0.09) as well as apparently normal left ventricular function (p = 0.11) to derive greatest benefit. CONCLUSIONS Physiologic pacing reduces the annual rate of development of chronic AF in patients undergoing first pacemaker implant. Age > or =74 years, SA node disease and prior AF predicted the development of CAF. Patients with structurally normal hearts appear to derive greatest benefits.
منابع مشابه
Canadian Trial of Physiological Pacing: Effects of physiological pacing during long-term follow-up.
BACKGROUND The Canadian Trial of Physiological Pacing (CTOPP) reported that the risk of stroke or cardiovascular death was similar between patients receiving ventricular versus physiological pacemakers at the end of the original follow-up period of 3 years. However, the occurrence of atrial fibrillation was significantly less frequent with physiological pacemakers. To assess a potential delayed...
متن کاملRelationship between pacemaker dependency and the effect of pacing mode on cardiovascular outcomes.
BACKGROUND A recently completed trial, the Canadian Trial of Physiological Pacing (CTOPP), showed that physiological pacing did not significantly reduce mortality, stroke, or heart failure hospitalization, but it did show that atrial fibrillation occurred less frequently in patients with physiological pacing. Many pacemaker patients experience only transient bradyarrhythmias with an adequate un...
متن کاملPacemaker selection : time for a rethinking of complex pacing systems : reply
We appreciate the interest in our article expressed by Silberbauer and colleagues. We are surprised to read that we ‘advocate VVI systems instead of DDD systems because of non-inferiority with regard to stroke and mortality as shown by MOST, CTOPP, PASE, and UKPACE.’ Indeed, we never mentioned UKPACE trial, published in July 2005, until the submission of our article. UKPACE trial (in which John...
متن کاملEffects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.
Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...
متن کاملEffects of Physiological Pacing During Long-Term Follow-Up
Background—The Canadian Trial of Physiological Pacing (CTOPP) reported that the risk of stroke or cardiovascular death was similar between patients receiving ventricular versus physiological pacemakers at the end of the original follow-up period of 3 years. However, the occurrence of atrial fibrillation was significantly less frequent with physiological pacemakers. To assess a potential delayed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 38 1 شماره
صفحات -
تاریخ انتشار 2001