Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.
نویسندگان
چکیده
PURPOSE To evaluate variations in the position of the phakic iris claw lens (Artisan, Verisyse) and the natural crystalline lens during the accommodation process. METHODS We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. RESULTS There was a forward shift of the phakic iris claw lens with a mean of 70 microm (8-178 microm) of the optical path length (OPL). At the same time the anterior pole of the natural lens showed a forward mean movement of 85 microm (4- 260 microm). CONCLUSIONS An anterior displacement of the iris-claw phakic lens was shown in a series of eyes during the accommodation process. As this displacement goes along with the forward displacement of the anterior pole of the crystalline lens, the preoperative measurement of the latter might provide some additional information about the position of the iris claw lens in the accommodative state after implantation.
منابع مشابه
Two-year follow-up of the Artisan/Verisyse iris-supported phakic intraocular lens for the correction of high myopia.
PURPOSE To evaluate the implantation of Artisan/Verisyse phakic intraocular lenses (pIOLs) (Advanced Medical Optics) as an effective and safe method for the correction of high myopia. SETTING Department of Ophthalmology, John A. Moran Eye Center, University of Utah Medical Center, Salt Lake City, Utah, USA. METHODS This retrospective outcomes trial examined the implantation of Artisan/Veris...
متن کاملIris-claw (Artisan®/Artiflex®) phakic intraocular lenses for high myopia and high hyperopia
Ophthalmology Department, Hospital de Clínicas de Porto Alegre and OftalmoCentro, Porto Alegre, RS, Brazil Av. Nilo Peçanha, 724/401, Porto Alegre, RS, CEP 90.470-000, Brazil Author for correspondence: Tel.: +55 513 330 7733 Fax: +55 513 330 7733 [email protected] Artisan/Artiflex phakic intraocular lenses (pIOLs) demonstrate reversibility, high optical quality with better best specta...
متن کاملComparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
PURPOSE To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometr...
متن کاملReversal of myopic anisometropic amblyopia with phakic intraocular lens implantation.
PURPOSE To report a case of reversal of myopic anisometropic amblyopia with phakic intraocular lens implantation. METHODS A 6-year-old boy with anisometropic amblyopia with spherical equivalent refraction of right eye: -14.00 -3.00 x 100 degrees, left eye: -0.50 -3.25 x 90 degrees, was treated for 2 years with occlusion to the left eye, with poor results. Refractive surgery was planned becaus...
متن کاملUltrasound biomicroscopy of the Artisan phakic intraocular lens in hyperopic eyes.
PURPOSE To study in situ the intraocular position of the Artisan iris-claw intraocular lens (IOL) (model 203) (Ophtec) in phakic hyperopic eyes using ultrasound biomicroscopy (UBM). METHODS Echograms of the anterior chamber were taken preoperatively and 24 to 317 days postoperatively in 4 eyes implanted with the Artisan IOL (power +4.0 to +6.0 diopters). The preoperative anterior chamber dept...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 17 6 شماره
صفحات -
تاریخ انتشار 2007