Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patient positioning technique and a rapid dynamic acquisition protocol, 30 patients underwent planar imaging with teboroxoime while at rest and after maximal treadmill exercise. Postexercise scans were completed in an average time (mean +/- SD) of 4.4 +/- 1.6 min, with 4.8 +/- 1.5 min for the views at rest. These results were compared with coronary arteriography or thallium scintigraphy after treadmill exercise, or both. Diagnostic agreement (abnormal versus normal) was present in 28 of the 30 patients (p less than 0.001). Regarding physiologic assessment as compared with thallium scintigraphy, the finding of infarction and ischemia was concordant in 89% and 86% of patients, respectively. This report describes the initial use of teboroxime with a rapid dynamic planar imaging technique, resulting in a high correlation with exercise thallium scintigraphy. Delayed postexercise images obtained 5 to 10 min after exercise demonstrated rapid disappearance of exercise-induced defects noted on the initial (0 to 5 min) postexercise views. The rapid differential washout with teboroxime has not been previously described and the possible clinical significance is discussed.
منابع مشابه
Diagnostic Value of Ankle Brachial Index for Myocardial Ischemia in Asymptomatic Diabetic Patients and Comparison with Myocardial Perfusion Imaging
Objective: The ankle-brachial index (ABI) as a simple test which can detect peripheral arterial disease (PAD). Therefore in this study we try to evaluate the diagnostic value of ABI for silent myocardial ischemia in diabetic patients and compare the results with myocardial perfusion imaging (MPI) results. Materials and Methods: All 149 diabetic patients in this study were categorized according...
متن کاملComparison of technetium-99m teboroxime tomography with automated quantitative coronary arteriography and thallium-201 tomographic imaging.
Technetium-99m (Tc-99m) teboroxime is a new perfusion tracer that is highly extracted and rapidly cleared by the myocardium. To determine the feasibility of Tc-99m teboroxime imaging in the diagnosis of patients with suspected coronary artery disease, 30 patients underwent single photon emission computed tomography imaging with Tc-99m teboroxime (25.2 +/- 1 mCi) at peak exercise and again 60 mi...
متن کاملTechnetium-99m-Teboroxime: A New Agent for Myocardial Perfusion Imaging
The assessment of myocardial perfusion by nuclear scintigraphy is an important diagnostic tool for the evaluation of patients with ischemic heart disease. Although a variety of radiopharmaceuticals have been used to assess coronary blood flow, thallium-201 ( 01 Tl) has become the most commonly used imaging agent since its introduction for clinical use by Lebowitz eta!. in 1973 (J). Thallium-20 ...
متن کاملDiagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease
Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...
متن کاملTc-99m-MIBI in evaluation of myocardial perfusion [Persian]
Tc-99m-MIBI is an isonrtrile derivative used for evaluation of myocardial perfusion in recent years. In this preliminary report, 7 patients with coronary artery disease are evaluated with Tc-99m-MlBl stress planar and sped studies. Good correlation with coronary angiography is observed in these cases. In view of inherent technical problems present with thallium 201, Tc-99m-MIBi is a good ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 16 6 شماره
صفحات -